8.11 ENTRY DELAY
Select the entry delay timer for this zone. Entry delay timers 1 and 2 are programmed in
section 6.4.
8.12 CROSS ZONE
Select YES to enable cross zoning for this zone. Cross zoning requires this zone to trip twice,
or this zone and another cross zoned zone to trip, within a programmed time before an alarm
report is sent to the receiver.
When a cross zoned zone trips, the bell and Output action assigned to the zone activates.
See section 7.4. The cross zone time specified in System Options begins to count down. See
section 6.6. If another cross zoned zone in the system faults, or if the first zone restores and
faults again before the cross zone time expires, the panel sends an alarm report.
If no other cross zoned zone in the system trips before the cross zone time expires, the panel
sends only a fault report from the first zone to the receiver.
Cross zoning is not compatible with Fire Verify zone types:
You cannot enable cross zoning for Fire Verify zones.
8.13 PRIORITY
Selecting YES allows you to provide additional protection for a zone by requiring it to be in a
normal condition before its assigned area can be armed. A priority zone cannot be bypassed.
A Priority zone not in a normal condition cannot be armed. If a user attempts to arm the area,
the keypad displays the bad zone name followed by PRIORITY ZONE and the arming is
stopped.
8.14 ZONE NUMBER
Enter the zone number you want to program next. Return to section 8.1 and follow the
descriptions of each programming prompt. If all zones are programmed, press the ARROW
key at the ZONE NO: – display to continue.
8 - ZONE INFORMATION
PRIORITY NO
ENTRY DELAY: 1
CRS ZONE NO
ZONE NO: –