5.1 SYSTEM REPORTS
This section of the Programmer allows you to select the reports the XR10 sends to the
receiver.
5.2 OPENING/CLOSING REPORTS
YES allows the panel to send opening/closing reports by user to the receiver.
5.3 ABORT REPORT
YES allows the panel to send an alarm abort report to the receiver any time an alarm report
has also been sent and the Bell Cutoff time has not expired. See Bell Cutoff section 7.2.
The area must be disarmed and no alarmed zones can still be armed.
5.4 ZONE RESTORAL REPORTS
This option allows you to specify whether the panel sends zone restoral reports and also
when they'll be sent.
NO - Restoral reports are not sent by the panel.
YES - The panel always sends zone restoral reports at the time the zone restores from an
alarm or trouble condition.
DISARM - The panel sends zone restoral reports when a zone that has restored from an
alarm or trouble is disarmed. Twenty-four hour zones send restorals immediately.
5.5 BYPASS REPORTS
YES allows the panel to send all zone bypass, reset, and force arm reports to the receiver.
The bypass report includes the zone number, zone name, and the user number of the
individual bypassing the zone.
5.6 CODE CHANGE REPORTS
YES allows the panel to send all code additions, changes, and deletions to the receiver. The
code change report includes the user number added or deleted and the user number of the
individual making the change.
5.7 AMBUSH
YES allows an ambush report to be sent anytime user code number one is entered at a
keypad. Selecting NO disables the ambush report and allows user code number one to
operate the same as all other codes.
5 - SYSTEM REPORTS
SYSTEM REPORTS
ABORT NO
OPN/CLOS YES
RESTORAL: YES
CODE CHG YES
AMBUSH NO
BYPASS YES
NO YES DISARM