11.4 Zone Type Specifications
This section describes applications for the default zone types in Zone Information programming.
The XR10 panel contains 11 default zone types for use in configuring the system. These zone types provide the most
commonly selected functions for their applications. All zone types except the Arming zone type can be customized by
changing the variable options listed below.
Description of the programmable zone options
Below is a description of the various zone options shown on the table above. For additional information, read through
the Zone Information section of this manual.
Zone Type Defaults - These are complete spellings of the abbreviations used for the zone types.
Type - These are the abbreviations you'll see on the keypad for the zone types.
Area - This is either Interior, Bedroom, or Perimeter.
Message - A = alarm report, T = trouble report, L = local with no report, - (dash) = no report.
Output - This refers to the four XR10 relay outputs only.
Action - This selects the type of relay output: S = steady, P = pulse, M = momentary, and F = follow
Swinger Bypass - Allows the zone to be automatically shunted after three trips.
Entry Delay - Selects the entry delay timer used for this zone.
Cross Zone - Provides cross zoning for this zone.
Priority - Requires this zone to be in a normal condition before the area can be armed.
11 - APPENDIX
– = This function is not enabled for this zone type.
= These zone functions are not available for this zone type.
Message
Output
Action
Message
Output
Action
Message
Output
Action
Message
Output
Action
Swinger Bypass
Entry Delay
Cross Zone
Priority
ZONE INFORMATION Type Area Disarmed Disarmed Armed Armed
Open Short Open Short
- - NT
Assign Area & Disarmed condition
for NT, DY, EX, A1, A2, AR only DY EX
INT
Assign Prewarn and Entry Delay FI PN
for EX only BDRM
EM SV A 1 S A 1 S A 1 S A 1 S N 1 N N
PERIM
A1 A2 T to P T to P T to P T to P or or or or
FV AR L 4 M L 4 M L 4 M L 4 M Y 2 Y Y
Zone Type Defaults Abbr. - F - F - F - F
NIGHT NT PERIM - 0 - - 0 - A 0 - A 0 - Y N N
DAY DY PERIM T 0 - T 0 - A 0 - A 0 - Y N N
EXIT EX PERIM - 0 - - 0 - A 0 - A 0 - Y 1 N N
FIRE FI T 0 - A 0 - N N N
PANIC PN T 0 - A 0 - N N N
EMERGENCY EM T 0 - A 0 - N N N
SUPERVISORY SV T 0 - A 0 - N N N
AUXILIARY 1 A1 PERIM T 0 - A 0 - T 0 - A 0 - N N N
AUXILIARY 2 A2 PERIM T 0 - A 0 - T 0 - A 0 - N N N
FIRE VERIFY FV T 0 - A 0 - N N
ARMING AR ALL