Dimplex DF3033ST Indoor Fireplace User Manual


 
8 www.dimplex.com
Fireplace Installation
New Wall Construction
Select a suitable location that
is not susceptible to moisture and
is away from drapes, furniture and
high trafc.
Place the replace in the
desired location to see how it will
look in the room.
Mark the desired location on
the oor and store the replace in
a safe, dry and dust free location.
Use studs to frame an
opening of 31 ¾ inches (807 mm)
wide x 22 ¾ inches (578 mm)
high x 9 ½ inches (241 mm) deep.
Figure 1
22 ¾”
(578 mm)
31 ¾”
(807 mm)
9 ½”
(241 mm)
Option #1 - The power cord can
be lead from behind the trim and
along the wall to an outlet near
the replace.
Option #2 - A new outlet can be
installed inside the new frame
construction. Plug the unit into
a 15 Amp, 120 Volt outlet. If the
cord does not reach, you may
use an extension cord rated for a
minimum of 1875 Watts.
Option #3 - Hardwire
Wire a dedicated, properly
fused circuit with 120 Volt,
15 Amp rating. Allow up to eight
(8) feet (2.4 m) of service cable
for connecting power supply to
junction box on replace when
installing after nishing wall.
CAUTION: Use two
conductor, non-metallic sheath
cable with ground wire (three
(3) wires total) for the incoming
power supply on replace
inserts. Use appropriate wire
to meet local and national
electrical codes for rated
power consumption.
Remove the outer jacket and