Desa (V)T36N SERIES Indoor Fireplace User Manual


 
www.desatech.com
108661-01F 3
12. Do not use this replace to cook food or burn paper or other
objects.
13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.)
in this replace. Use only the gas type indicated on replace
nameplate.
14. This appliance, when installed, must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
15. Do not use replace if any part has been exposed to or under
water. Immediately call a qualied service person to arrange
for replacement of the unit.
16. Do not operate replace if any log is broken.
17. Do not use a blower insert, heat exchanger insert, or other ac-
cessory not approved for use with this replace.
18. Do not operate replace with glass door removed, cracked, or
broken.
19. Provide adequate clearances around air openings.
PRODUCT IDENTIFICATION
SAFETy INFORMATION
Continued
Figure 1 - Tudor Direct-Vent Fireplace with Millivolt Ignition
LOCAL CODES
Install and use replace with care. Follow all local codes. In the
absence to local codes, use the current National Fuel Gas Code
ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal-
lation Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
These are a few facts that can help you understand and enjoy your
direct-vent replace:
The venting system may be routed to the outside of your home
in several ways. It may vent through the roof (vertical) or it may
vent to an outside/exterior wall (horizontal). The vent pipe instal-
lation is very important to allow for proper operation. You must
follow the venting instructions very carefully for either vertical
or horizontal applications.
This replace may be installed in any room of your house
provided all local codes and these installation instructions are
followed.
This replace does not require electricity to operate.
Only the blower requires electricity if installed and if you plan to
install the blower at a later date, do not forget to wire the outlet
at the bottom of the replace when framing.
A piezo ignitor and ceramic electrode create spark to ignite the
pilot light. It does not require any matches, batteries or any other
sources of ignition to light the pilot.
Each time you turn on your replace, you may notice some
amount of condensation on the inside of the replace glass. This
is normal and will disappear after 10-20 minutes of operation.
Your direct-vent gas replace system (replace and venting) is a
balanced and sealed gas operating unit. It requires approximately 10-
20 minutes of operating time before the ame pattern stabilizes.
Glass
Door
Assembly
Blower Switch
(Optional Installation)
Piezo
Ignitor
Control
Valve
Log
Set
Grate
Assembly
Lava
Rock
Glowing
Embers
Upper Louver
Panel
Lower
Louver
Panel
Flue Collar
Nailing
Flange
ON/OFF/REMOTE Switch
(Optional Installation)