VENTING INSTALLATION
Continued

Instructions for chase installations are
included with the chase style termination
chosen. In a multiple chase installation, be
sure to provide adequate distance between
terminations to prevent smoke spillage from
one termination to another. Terminations must
be separated a minimum of 30" center to cen-
ter and stacked at a minimum vertical height
difference of 18" (see Figure 26).
Note: If a decorative shroud is to be installed,
contact the manufacturer for specications.
FINISHING FIREBOX

Any noncombustible material may be used
for facing (glass, tile, brick, etc.) as long as
proper clearances are adhered to and rebox
openings are not obstructed in any way (see
Figure 27).
Use only heat resistant, noncombustible mor-
tar or adhesive when securing facing material
to front of rebox. When placing facing at
upper edge of effective opening of rebox,
provide “L” shaped piece of metal extending
full width of opening (see Figure 27).
Secure with sheet metal screws at a distance
high enough from edge so it doesn't interfere
with operation of doors. This assures that fac-
ing material will not block openings.
30" Min.
30" Min.
18"
Min.
Typ.
Figure 26 - Multiple Chase Installation
1"
Space
Screen
Chase
Top
1" Non-
com-
bustible
Spacer
“L” Shaped
Metal
Support
Noncombustible
Facing Material
Noncombustible
Facing Material
Do Not
Block
Opening
Figure 27 - Fireplace Facing (Your
Fireplace May Vary from Illustration)