INSTALLATION
Continued
CAUTION: Do not remove
the data plates attached to the
heater base assembly. The data
plates contain important war-
ranty and safety information.
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
INSTALLING GAS LOG INTO STOVE
1. Remove log from carton.
2. Remove all protective packaging applied to
log for shipment.
3. Check log for any shipping damage. If dam-
aged (pieces larger than the size of a dime),
promptly inform dealer where you bought
heater.
4. Set one-piece log on heater base as shown in
Figure 12. Make sure middle section at bot-
tom of log is seated into "U" shaped cutout in
center of heater base. Log will fit securely on
base.
IMPORTANT:
Make sure log does not
cover any burner ports and does not touch the
stove cavity (see Figure 13).
5. Fasten back panel to stove with four (4)
M6 x 1bolts and washers.
6. Place freestanding stove in desired position
in room. Be sure to maintain clearances to
combustibles as outlined on page 8.
CAUTION: After installation
and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to HI, check
to see if flames contact any log.
If so, reposition logs according
to the log installation instruc-
tions in this manual. Flames con-
tacting logs will create soot.
H
I
L
O
O
F
F
P
I
L
O
T
O
N
Burner Porting Areas (double
slotted rectangular openings)
Figure 13 - Top View of One-Piece Log
Set on Gas Log Heater
Safety Pilot Location
One-Piece
Log Set
One-Piece
Log Set
"U" Shaped
Cutout in Chassis
Burner
Middle
Section at
Bottom of
Log Set
Figure 12 - Installing One-Piece Stove
Log Set
Heater Base
CONNECTING TO GAS SUPPLY
WARNING: This appliance
requires a 1/2" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.
WARNING: A qualified service
person must connect heater to
gas supply. Follow all local codes.
CAUTION: Never connect
propane/LP heater directly to the
propane/LP supply. This heater
requires an external regulator
(not supplied). Install the exter-
nal regulator between the heater
and propane/LP supply.