Desa SVYD18NRA Stove User Manual


 
www.desatech.com
113084-01E 17
2. Press the MANU button to turn on the
heater.
3. Press the POWER and LOCK buttons
together to turn off the heater.
Auto (Thermostatic) Mode
1.
Press the POWER and LOCK buttons together
to turn on the hand-held remote control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by press-
ing the TEMP + or - buttons.
4. Press the POWER and LOCK buttons
together to turn off the replace
Note: Do not leave the hand-held remote in the
AUTO mode close to the replace. The radiant
heat from the replace will turn off the replace.
Ideally, place the hand-held remote in the center
of the room facing towards the replace.
Note: Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the replace, the receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature exceeds
82 degrees Fahrenheit (28 degrees Centi-
grade), the hand-held remote control will
perform a safety override and shut the
replace off. This feature is not available
in the MANU mode.
2. The receiver continuously receives signals
from the hand-held remote to control the
room temperature. If the hand-held remote
is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver
will shut off the replace after 8 minutes.
Key Pad Lock Feature
This feature allows the user to lock/unlock
the keypad on the hand-held remote in the
MANU or AUTO mode to prevent inadvertent
operation (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
OPERATING HEATER
Continued
INSPECTING BURNERS
Check pilot ame pattern and burner ame pat-
terns often.
PILOT FLAME PATTERN
Figure 25 shows a correct pilot ame pattern. Figure
26 shows an incorrect pilot ame pattern. The in-
correct pilot ame is not heating the thermocouple.
This will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down.
If pilot ame pattern is incorrect, as shown in
Figure 26
turn heater off (see To Turn Off Gas to Appli-
ance, page 15
see Troubleshooting, page 19
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue and
have no yellow or orange color.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in
the tting at the burner entrance. These holes may
become blocked with dust or lint. Periodically
inspect these holes for any blockage and clean if
needed. Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner ame holes with
the heater running. All slotted burner ame holes
should be open with yellow ame present. All
round burner ame holes should be open with a
small blue ame present. Some burner ame holes
may become blocked by debris or rust, with no
ame present. If so, turn off heater and let cool.
Remove blockage. Blocked burner ame holes
will create soot.
Pilot Burner
Figure 25 - Correct Pilot Flame Pattern
(Propane/LP Shown)
Figure 26 - Incorrect Pilot Flame Pattern
(Propane/LP Shown)
Thermocouple
Pilot Burner
Thermocouple