Desa M42(B,H) Indoor Fireplace User Manual


 
www.desatech.com
108795-01V 13
GAS LINE HOOK-UP
WARNING:Gaslinehookup
should be done by your gas
supplier ora qualiedservice
person.
WARNING: Before you pro-
ceed,makesureyourgassupply
is OFF.
A manual shutoff valve has been included in
the appliance’s gas supply system. You may
consider installing an extra gas shutoff valve
outside appliance’s enclosure (check with
local codes) where it can be accessed more
conveniently with a key through a wall as
shown in Figure 18.
In conformance with local codes, route a
1/2" NPT gas line to appliance through hole
in left side of rebox or sub-oor as shown
in Figure 19.
CAUTION:Donotkinkex-
iblegasline.
Installing 9-Volt Battery in Hand-Held
RemoteControlUnit
1. Remove battery cover on back of remote
control unit.
2. Attach terminal wires to battery (not
included). Place battery into battery hous-
ing. Note: Only use alkaline battery.
3. Replace battery cover onto remote control
unit.
Figure 17 - Installing Battery in Hand-
Held Remote Control Unit
Battery Cover
9-Volt
Battery
Terminal
Wires
Remote
Control Unit
Battery
Housing
INSTALLATION
Continued
DESA Heating, LLC recommends that a black
iron gas line be routed from the gas source,
through a sediment trap (see Figure 20) and
into appliance. Once connected through ap-
pliance, a exible gas line may be used for
ease of installation to gas control valve (see
Figure 21, page 14).
Before connecting black iron gas line to inside
of appliance a sediment trap must be included
outside appliance between gas line and gas
shutoff valve. It must extend down 3" beyond
center of pipe. Prepare incoming black iron
gas line with teon tape or pipe joint com-
pound (Check with local building codes).
Figure 18 - Manual Shutoff Valve
Installation
Typical Exterior Wall Gas
Shutoff Installation
Key
Extension
Shutoff
Valve
Figure 19 - Routing Incoming Gas Line
A
1/2" NPT
Incoming Black
Iron Gas Line
7"
7"
Alternate Gas Supply
Through Sub-Floor
M36(B,H),
M36P(B,H
VM36(B,H),
VM36P(B,H)
M42(B,H),
M42P(B,H)
VM42(B,H),
VM42P(B,H)
A 8
5
/
8
" (21.9 cm) 10
1
/
2
" (26.7 cm)
Incoming
1/2" Gas Line
Permitted by
Local Codes
Sediment
Trap (Not
Supplied)
Figure 20 - Sediment Trap
3" Min.
(7.6 cm)