Desa LGCFTN Indoor Fireplace User Manual


 
www.desatech.com
119508-01A 9
Note: Your replace is designed to be used in zero
clearance installations. Wall or framing material
can be placed directly against any exterior surface
of your replace, except where standoff spacers are
integrally attached. If standoff spacers are attached
to your replace, these spacers can be placed directly
against wall or framing materials.
Use the dimensions shown for rough openings to
create the easiest installation (see Built-In Fire-
place Installation, page 10).

Use the correct gas type (natural or propane/LP)
for your unit. If your gas supply is not correct, do
not install replace. Call dealer where you bought
replace for proper type replace.
   
-
 

INSTALLATION ITEMS
Before installing replace, make sure you have the
items listed below.
external regulator - propane/LP only (supplied
by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection *
ground joint union
sediment trap
tee joint
pipe wrench
* A CSA design-certied equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certied equipment shutoff valve from your
dealer. See Accessories, page 27.
Note: If desired, purchase a four-sided brass trim kit
for built-in installations. See Accessories, page 27.

WARNING: Maintain the
minimum clearances shown
  


INSTALLATION
Continued
Figure 9 - Mounting Clearances As
Viewed From Front of Fireplace Shown
with Optional Mantel
Figure 8 - Mounting Clearances As
Viewed From Front of Fireplace Shown
Built In The Wall
6"
Minimum
From
Sides Of
Fireplace
Left
Side
CEILING
36" Minimum
FLOOR
Right
Side
Top Of
Mantel Can
Be Flush
With Wall
Left
Side
CEILING
Right
Side
36"
Minimum
You can recess rebox into the wall. You can
also position replace in the optional cabinet or
corner mantels. IMPORTANT: Only use optional
cabinet or corner mantels specied in this manual.
Purchase the optional mantel from your dealer (see
Accessories, page 27).
WARNING: Never install the

 
• in a recreational vehicle
• where curtains, furniture, cloth-

are less than 36" from the front,

 
 
• in windy or drafty areas