Desa LGCFTN Indoor Fireplace User Manual


 
www.desatech.com
119508-01A10
-
    
currents move heat to wall sur-

  
   

  
smoke, aromatic candles, clean-



IMPORTANT: Vent-free replaces add moisture
to the air. Although this is benecial, installing re-
place in rooms without enough ventilation air may
cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, page 6.
Note: When installing replace directly on carpet-
ing, tile or other combustible material, other than
wood ooring, the replace shall be installed on a
metal or wood panel extending the full width and
depth of the replace.
CAUTION: If you install the

 

 

For convenience and efciency, install replace
where there is easy access for operation, inspec-
tion and service.
in coldest part of room
An optional blower kit is available from your
dealer. See Accessories, page 27. If planning to use
blower, locate replace near an electrical outlet.

Built-in installation of this fireplace involves
installing replace into a framed-in enclosure.
This makes the front of replace ush with wall.
An optional brass trim kit accessory is available
(see Accessories, page 27). Brass trim will extend
past sides of replace approximately 1/2". This
will cover the rough edges of the wall opening. If
installing a built-in mantel above the replace, you
must follow the clearances shown in Figure 14,
page 12. Follow the instructions below to install
the replace in this manner. Note: Your replace is
designed to be used in zero clearance installations.
Wall or framing material can be placed directly
against any exterior surface on the rear, sides or
top of your replace.
Actual Framing
Height 26" 26
7
/
8
"
Front Width 26
3
/
4
" 26
7
/
8
"
Depth 9
1
/
2
" 10
1
/
2
"
Bottom 3/4" 3/4"
1. Frame in rough opening. Use dimensions
shown in Figure 10 for the rough opening.
If installing in a corner, use dimensions shown
in Figure 11 for the rough opening. The height
is 26
7
/
8
" which is the same as the wall opening
above.
36
5
/
8
"
25
7
/
8
"
51
3
/
4
"
26
7
/
8
"
26
7
/
8
"
26
7
/
8
"
3/4" Off
The Floo
r
Minimum
10
1
/
2
"
Figure 10 - Rough Opening for Installing
in Wall
Figure 11 - Rough Opening for Installing
in Corner
INSTALLATION
Continued