Desa LGCFTN Indoor Fireplace User Manual


 
www.desatech.com
119508-01A4
SAFETY INFORMATION
Continued
LOCAL CODES
Install and use replace with care. Follow all local
codes. In the absence of local codes, use the latest
edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
PRODUCT INFORMATION
Figure 1 - Vent-Free Gas Compact
Fireplace
Ignitor
Button
Screen
Fireplace
Cabinet
Log
Set
Control
Knob
7. This replace is designed to be smokeless. If
logs ever appear to smoke, turn off replace
and call a qualied service person. Note:
During initial operation, slight smoking could
occur due to log curing and replace burning
manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 20.
9. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
10. This replace needs fresh air ventilation to run
properly. This replace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS shuts down the replace if not enough
fresh air is available. See Air for Combustion
and Ventilation, page 6. If replace keeps
shutting off, see Troubleshooting, page 22.
11. Do not run replace
• where ammable liquids or vapors are used
or stored.
• under dusty conditions.
12. Do not use this replace to cook food or
burn paper or other objects.
13. Never place any objects in the replace or on
logs.
14. Do not use replace if any part has been under
water. Immediately call a qualied service
technician to inspect the room replace and
to replace any part of the control system and
any gas control which has been under water.
15. Turn off and unplug replace and let cool be-
fore servicing. Only a qualied service person
should service and repair replace.
16. Operating replace above elevations of 4,500
feet could cause pilot outage.
17. Do not operate replace if any log is broken.
Do not operate replace if a log is chipped
(dime-sized or larger).
18. To prevent performance problems, do not use
propane/LP fuel tank of less than 100 lbs.
capacity (propane/LP units only).
19. Provide adequate clearances around air
openings.