OPERATION
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
realistic dancing, yellow flames. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANSI Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free
heaters. This heater may also be operated as
a vented decorative (ANSI Z21.60) product
by opening flue damper (non-thermostat
models only).
SAFETY PILOT
This heater has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
shuts off the heater if there is not enough
fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
1. Remove logs and heater base assem-
bly from carton.
Note:
Do not pick up
heater base assembly by burners. This
could damage heater. Always handle
base assembly by grate.
2. Remove all protective packaging ap-
plied to logs and heater for shipment.
3. Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.
UNPACKING
PRODUCT
FEATURES
Optional
Remote
Control
Front Log
Control Knob
Back Log
Base Grate
Burner
Piezo Ignitor
Crossover Log
Middle Log
Optional Selector Switch
Flame Adjustment Knob
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANSI Z223/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs
are required, thermostat operation is not
permitted.
CAUTION: Do not remove
the data plates attached to the
heater base assembly. The data
plates contain important war-
ranty and safety information.
14. Turn heater off and let cool before ser-
vicing, installing, or repairing. Make sure
the remote selector switch is in the OFF
position. Only a qualified service person
should install, service, or repair heater.
15. Make sure the remote selector switch is
in the OFF position when you are away
from home for long periods of time.
16. This heater must not be connected to
any external electrical source.
17. Operating heater above elevations of
4,500 feet may cause pilot outage.
18. Provide adequate clearances around air
openings.
SAFETY
INFORMATION
Continued