Desa CGD3924NRA Electric Heater User Manual


 
16
107553
UNVENTED NATURAL GAS LOG HEATER
For more information, visit www.desatech.com
TO TURN OFF GAS
TO APPLIANCE
1. Follow steps 1 through 6 under Light-
ing Instructions, pages 15 and 16.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11 under Light-
ing Instructions, column 1.
1. After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI and
LO. Slide the selector switch to the
REMOTE position.
Note:
The burn-
ers may light if hand-held remote ON
button was on when selector switch
was last turned off. You can now turn
the burners on and off with the hand-
held remote control unit.
IMPORTANT:
Do not leave the se-
lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.
IMPORTANT:
Be sure to press the
ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.
CGHRC Series Operation:
2a. Press the ON/OFF button to turn the
burners on and off. When turning
burners off, the pilot will remain lit.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions
on pages 15 and 16.
OPERATING
HEATER
Continued
Figure 35 - Pilot
CAUTION: Do not try to adjust
heating levels by using the equip-
ment shutoff valve.
WARNING: Make sure the se-
lector switch is in the OFF position
when you are away from home for
long periods of time. Heater will
come on automatically with selec-
tor switch in the ON position.
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held re-
mote: Set selector switch in the OFF
position to keep from draining battery.
Shutting Off Burners Only
(pilot stays lit)
You may shut off the burners and keep
the pilot lit by doing one of the following:
1. Turn control knob clockwise
to the PILOT position.
2. Use remote control manual OFF button.
3. Set selector switch in the OFF position.
Ignitor Electrode
Pilot Burner
MANUAL LIGHTING
PROCEDURE
OPTIONAL REMOTE
OPERATION
Note:
All remote control accessories must
be purchased separately (see Accessories,
page 27). Follow instructions included
with the remote control.
Thermostat Control Operation
(Optional CGHRCTA Only) The ther-
mostat control setting on the remote con-
trol unit can be set to any comfort level
between WARMER and COOLER. The
burner will turn on and off automatically
to maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount
of space to be heated, the output of the
central heating system, etc.
WARNING: Burners will come
on automatically within one
minute when the remote selector
switch is in the ON position after
the pilot is lit.
4. Press in and turn control knob clock-
wise to the OFF position.
5. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, page 15, column 2. If you
don’t smell gas, go to the next step.
6. Press in and turn control knob coun-
terclockwise
to the PILOT
position. Press in control knob for five
(5) seconds (see Figure 34, page 15).
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.
7. With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.
Note:
If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure.
8. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps
4 through 8.
9. Slightly push in and turn control
knob counterclockwise to
the ON position.
10. Wait one minute and switch selector
switch to the ON position to light
burners.
11. Set flame adjustment knob to any
level between HI and LO.