Desa 50 Electric Heater User Manual


 
9
099618
4. Plug heater’s power cord into approved, grounded, three-wire extension cord.
Extension cord must be at least six feet (1.8 meters) long.
Extension Cord Size Requirement
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm
2
) rated cord
11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm
2
) rated cord
101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm
2
) rated cord
5. Plug extension cord into standard 120 volt/60 hertz, 3-prong grounded outlet.
Heater will start when extension cord is plugged into outlet. If not, push in
heater’s safety control reset button (see Figures 6 and 7).
Figure 6 - Safety Control Reset
Button, 35/50/70 Models
Figure 7 - Safety Control Reset
Button, 100/150 Models
To Stop Heater
1. Unplug extension cord from outlet.
To Restart Heater
1. Wait two minutes after stopping heater.
2. Repeat steps under To Start Heater.
Safety
Control
Reset
Button
Safety
Control
Reset
Button
OPERATION
Continued