Daewoo Split Airconditioning System Air Conditioner User Manual


 
INSTALLATION (CONTINUED)
7
NOTES:
This appliance must be installed according to National
power supply requirement.
If the supply cord is damaged, it must be replaced by
the manufacturer or its service agent or a similarly qual-
ified person in order to avoid a hazard.
Make sure the Indoor unit’s AC cord is not connected to
AC power when connecting the indoor/outdoor wire.
When connecting wires, make sure they are fully insert-
ed and minimum copper wire is exposed. If they are
not, shorting, overheating, no operation, etc. may occur.
Be sure to comply with local codes on running a wire
from the indoor to the outdoor unit.
1. Open the connection cover on the indoor unit to ac-
cess the connection area.
Remove the Connection
Cover.
• Loosen one screw for fixing
the Connection Cover.
• Loosen one screw at the
Connection Cover.
• Remove the Connection
Cover.
2. Fish the indoor/outdoor wire from the rear of the in-
door unit through the front of the unit.
For easier connection, make sure enough wire is
pulled through the front.
Use the wire as shown below:
Brown
Yellow/Green
Blue
Blue
Black
INSTALLING THE INDOOR/OUTDOOR WIRE TO THE INDOOR UNIT FOR AC CONNECTION
The Indoor/Outdoor wire is used to supply AC from the Indoor unit to the Outdoor unit. To install the indoor/outdoor wire,
follow the procedures below.
3. To connect wires, loosen the screw in the Terminal
Block and insert the correct wires like following fig-
ure. Connect the Brown wire to the “L” connection,
Yellow/Green wire to the “ ” connection, the Blue
wire to “Y” connection, the Blue wire to “1” connec-
tion and the Black wire to “2” connection.
Blue
Blue
Black
L
Y
1
2
Yellow/Green
Brown
Screw
Connection cover