Crown Boiler CLBF68-112 Furnace User Manual


 
36
USERS INFORMATION
c WARNING:
The area around the furnace should be kept free and clear of flammable vapors,
liquids, and material, especially papers and rags.
NEVER burn garbage or refuse in the furnace. NEVER try to ignite oil by tossing
burning papers or other material into the furnace.
This oil furnace is designed to burn No. 2 distillate fuel (home heating) oil ONLY.
NEVER USE GASOLINE OR A MIXTURE OF OIL AND GASOLINE.
DO NOT attempt to make repairs to the furnace yourself!
Operating Instructions
For your safety, read this information before operating this furnace.
c WARNING: Failure to follow these instructions may result in fire or explosion
causing property damage, personal injury, or loss of life.
WHAT TO DO IN THE EVENT OF AN OIL LEAK:
Do not try to operate this or any other nearby appliance.
If present, close the manual oil shutoff valve on the fuel oil supply line.
Immediately call a qualified heating contractor for service.
If you cannot reach a qualified heating contractor, call the fuel oil supplier of the
fire department.
DO NOT use this furnace if any component was underwater. Immediately call a
qualified heating contractor to inspect the furnace and replace any part of the furnace
control system that was underwater.
This furnace does not have a pilot light. It is equipped with an electronic ignition system
that automatically lights the burner. DO NOT attempt to light the burner by hand.
TO OPERATE THIS FURNACE:
1) Adjust the room thermostat to the lowest setpoint and set the operating mode, if
equipped, to “OFF”.
2) Turn off all electric power to the furnace at the disconnecting switch.
3) Turn the manual oil shutoff valve to the open or “ON” position.