Crown Boiler CLBF68-112 Furnace User Manual


 
35
The heat exchanger may also be cleaned through the flue pipe connection. With the
furnace turned off and at room temperature, carefully remove the vent connector and
the heat exchanger flue pipe, if equipped, to inspect and clean the heat exchanger.
The inner radiator of the heat exchanger may be cleaned from the inside of the
combustion chamber. This involves removal of the burner and the burner mounting
plate from the heat exchanger.
Using a portable light source with a mirror inserted through and into the heat exchanger,
check for an accumulation of soot, scale, and particulate matter on the walls and in the
base of the drum, or on the floor of the combustion chamber. If a significant
accumulation is present, it should be removed. Use a flexible wire brush to loosen the
deposits on the heat exchanger walls. Remove any loose foreign material using a
vacuum cleaner.
Replace all gaskets, if removed, with new (unused) gaskets. Reassemble the burner
mounting plate, burner flange, and new gaskets in the reverse order they were
removed. A rubber mallet, or equivalent tool, may be useful for reinstalling the caps in
the cleanout tubes.
Flue and Chimney
At least once a year, thoroughly inspect the heat exchanger flue pipe, the vent
connector, the chimney, or vent, and the barometric damper for signs of sagging, loose
connections, excessive corrosion, and deterioration. Clean, repair, or replace any
components for continued safe and proper operation of the furnace.