Coway CHP-06DL Water System User Manual


 
12 13
WATER FILTRATION PROCESS PLEASE KEEP IN MIND
The filter is the core technology of the
filtration
system. If you don’t use qualifying filter
or if you use an old filter that has expired, the system performance may degrade.
How to Use
NEO-SENSE FILTER
Reduces various foreign bodies that come from the feed water pipe such as dirt, sand,
rust particles, VOCs and chlorine.
MEMBRANE FILTER (RO)
POST-CARBON BLOCK FILTER
The RO(Reverse Osmosis) Membrane filter reduces Pentavalent Arsenic, Barium, Cadmium,
Mercury, Selenium, Radium 226/228, Trivalent chromium, Hexavalent chromium, Lead,
Nitrate/Nitrite. The influent water to the system shall include the following characteristics.
No organic solvents Chlorine : < 2 ppm pH : 7-8 Temperature : 41-95 (5-35 )
Iron : < 2 ppm Turbidity : < 1 NTU Hardness : < 1000 mg/L
It is a composite filter. The post-carbon filter removes odor of water and improve water
taste. And the filter sensor eliminates the dust particles in the post-carbon filter.
Restraints propagation of the microorganism inside water tank and enhances sanitation.
The 6-step water filtering system (CHP-06DL)
Disposed
Water
Outlet
NEO-SENSE
FILTER
POST-CARBON
BLOCK FILTER
MEMBRANE
FILTER
CERAMIC FILTER
CERAMIC FILTER
The disposed water shall be used for cleaning a toilet, a house, dishes, and as
water for sundry uses. However, please do not use it for potable water or
cooking water.
WARNING
This system conforms to NSF/ANSI 58 for the reduction of Barium, Radium
226/228, Cadmium, Lead and TDS as verified and substantiated by test data.
Water Filtration Process Please Keep In Mind
/
The summary for the proper installation of the water filtration system.
1 Connect the power cord to the
voltage rating that matches it on
the rating plate only.
2 Close main water supply valve
to separate the faucet.
3
Wind the teflon tape on the adaptor
and fit it to the pipe.
4 Connect the faucet with the
adaptor.
5 Connect ¼orange tubing with
the connector on the adaptor.
Do not turn the water pipe.
Shall install the adaptor with connector on
the cold water pipe.
Flush water through each filter at least 5
minutes before Connection