CFM UVLC18RN Indoor Fireplace User Manual


 
8 UVLC Series
Manufactured Fireplace
Damper Stop Installation
Damper Stop #3030176 is designed for use with CFM
Corporation BR, BC, SR, SC,TF and TL Series fire-
places.
1. Open the fireplace damper. The damper must be in
the open position in order to attach the damper stop.
2. From inside the fireplace, locate the damper locking
bracket on the left side of the combustion dome. (Fig.
5)
3. Align the two slots on either side of the cutout on the
damper stop with the two small holes on the angled
portion of the damper locking bracket. Attach the
damper stop with the screws provided. (Fig. 6)
NOTE: Some of the early units may not have the holes
in the end of the damper locking bracket. If this is the
case, use the damper stop as a template to drill two
1/8” holes in the damper locking bracket to mount the
damper stop.
LS761/Damper Clamp Location
968/598 UVL/UVHL
7/27/98
Damper
Stop
Damper
Stop
761
Fig. 4 Damper stop placement.
LS855
Attach damper stop
11/99
Damper Locking
Bracket
Damper
Stop
#3030176
Attachment Screws
- Two Provided
LS855
Fig. 6 Attach the damper stop.
LS854
Locate damper
lock bracket
11/99
Damper Locking Bracket
LS854
Fig. 5 Locate the damper locking bracket inside the fireplace
dome.