CFM UVLC18RN Indoor Fireplace User Manual


 
12 UVLC Series
The First Firing
On completing the gas line connection, a small amount
of air will be trapped in the gas line. When you first light
the unit with the pilot light, it will take a few minutes to
purge the trapped air. Once you have purged the gas
line, the pilot and burner will light and operate normally.
Subsequent lightings of the appliance will not require
purging the gas line.
When lit for the first time, the appliance will emit a slight
odor for an hour or two. This is due to paint and lubri
-
cants used in the manufacturing process curing under
heat. This is normal. You may wish to have the windows
open to dissipate any odors during the curing process.
Flame Appearance
To obtain proper operation, it is imperative that the pilot
and main burner flame characteristics are steady, not
lifting or floating. Refer to Figure 11 for proper burner
flame appearance and Figure 12 for proper pilot flame
appearance.
Typically, the top 1/8” of the thermopile should be en-
gulfed in the pilot flame. (Fig. 12)
P102
Honeywell pilot
flame
6/16/99 djt
Thermopile
P102
Fig. 12 Proper pilot flame appearance.
Operating Instructions
HV101a
Honeywell valve
UVL
3/18/99 djt
PILOT
ON
OFF
PILOT
ADJ
L
O
H
I
Fig. 10 Honeywell Valve.
Piezo Igniter
Regulator Knob
Control Knob
HV101a
LG116
log flames
11/99
Yellow
Flames
Fig. 12 Proper burner flame appearance.
Red glow
LG116