4 UVLC Series
Planning
Planning the installation is an important first step. It will
save time and money later in the actual installation. In
planning the installation, consider:
• Where the heater will be located.
• All components needed to complete the installation.
• DO NOT use this heater in sleeping quarters, mobile
homes, or in recreational vehicles.
• Installation and repair should be done by a qualified
service person.
• DO NOT use this heater if any part has been under
water. Immediately call a qualified technician to inspect
the appliance and replace any part of the control sys-
tem and any gas control which has been under water.
• When used as an unvented heater, always ensure
that there is adequate ventilation from the room where
the appliance is operating. This appliance is equipped
with and ODS (oxygen depletion sensor) pilot light safe-
ty system designed to shut off the appliance if enough
fresh air is not available.
THIS APPLIANCE MUST NOT BE USED WITH GLASS
DOORS IN A CLOSED POSITION .
Keep the burner and control compartment clean. See
installation and operating instructions supplied with the
heater.
WARNING: During manufacturing, fabricating, and
shipping, various components of this appliance are
treated with certain oils, films, or bonding agents.
These chemicals are not harmful, but may produce
annoying smoke and smells as they are burned off
during the initial operation of the appliance, pos-
sibly causing headaches or eye or lung irritation.
This is a normal and temporary occurrence. The
initial break-in operation should last 2-3 hours with
the burner at its highest setting. Provide maximum
ventilation by opening windows, doors, and the
chimney flue to allow odors to dissipate. Any odors
remaining after this initial break-in will be slight and
will disappear with continued use.
This appliance operates as an unvented domestic room
heater when fitted to a masonry or factory-built wood-
burning fireplace with the flue damper closed, or as
a decorative appliance when the flue damper is fully
open. It must not be used for any other purpose and
must be fitted in a masonry or factory-built fireplace or
ventless firebox enclosure.
State, provincial or local codes may only allow opera-
tion of this appliance in a vented configuration. Check
your state, provincial or local codes. If unvented room
heaters are not permitted, the fireplace vent damper
must be locked open at the minimum vent area required
by local codes or by the National Fuel Gas Code (ANSI
Z223.1/NFPA 54, latest edition) and CSA B149 Installa-
tion Codes for Gas Burning Appliances.
When installed as a Decorative Gas Appliance for
installation in a solid-fuel burning fireplace, a mini
-
mum permanent free opening of 29 square inches
must be maintained with a fixed damper stop pro-
vided with the appliance. Minimum flue size for this
appliance is 29 square inches.
Installation Precautions
1. This vent-free gas appliance and its components
have been tested and will operate safely when installed
in accordance with this Installation Manual. Read all
instructions before starting the installation, and follow
these instructions carefully \ installation to maximize the
appliance’s benefit and safety. Failure to follow them
will void your warranty and may present a fire hazard.
2. After opening the carton, refer to Parts Identification
on Page 15 and 16, and remove the various parts.
Report to your dealer if any parts were damaged in
shipment.
The CFM Corporation warranty will be voided by,
and CFM Corporation disclaims any responsibility
for, the following actions:
• Installation of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by
CFM Corporation.
• Improper positioning of the gas logs.
• Installation and/or use of any component
part or accessory not manufactured or approved
by CFM Corporation, not withstanding any inde-
pendent testing laboratory or other third-party
approval of such component part or accessory.
Any such action may create a possible fire hazard.
Consult your local building codes.
This heater shall not be installed in a confined
space unless provisions are provided for adequate
combustion and ventilation air.
WARNING
Improper installation, adjustment, alteration, ser-
vice, or maintenance can cause injury of proper-
ty damage. Refer to this manual. For assistance
or additional information, consult a qualified
installer, service agency, or the gas supplier.