Desa Tech CGFB32CC Indoor Fireplace User Manual


 
www.fmiproducts.com
124970-01A 3




   
will remain hot for a time after


-
dren when they are in the room


   
    
    
     






   

SAFETy
Continued
1. Do not use this rebox as a wood-burning
replace. Use only decorative unvented
room heaters (log sets).
2. Do not add extra logs or ornaments such
as pine cones, vermiculite or rock wool.
Using these added items can cause
sooting.
3. Use only the provided hood or appropri-
ate hood accessory. See Accessories on
page 17.
4. Vent-free gas log heaters installed in these
reboxes require fresh air ventilation to
run properly. See Air for Combustion and
Ventilation, page 6.
5. Do not run rebox
• where ammable liquids or vapors are
used or stored
• under dusty conditions
6. Do not use this rebox to cook food or
burn paper or other objects.
7. Turn rebox off and let cool before servic-
ing. Only a qualied service person should
service and repair rebox.
8. Operating rebox above elevations of
4,500 feet could cause pilot outage.
9. Do not use the rebox if it has been un-
der water due to the shock hazard that
could result with the blower accessary (if
installed) in place.
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel Gas
Code, ANSI Z223.1/NFPA 54*. Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANSI/NFPA70
(latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.