CFM Corporation DVT38IN Indoor Fireplace User Manual


 
25
Chateau™
20011956
Only glass approved by CFM Corporation
should be used on this fireplace.
1. Turn the fireplace OFF (including the pilot).
2. If the unit has been operating allow time for the
components to cool.
3. Using a Phillips screwdriver, unfasten two (2) screws
located at the top of the glass frame. (Fig. 34)
4. Tilt the glass frame at the top away from the unit.
Lift it carefully off the bottom door track and set on
padded surface.
It is necessary to periodically clean the glass. During
start-up, condensation, which is normal, forms on the
inside of the glass. This condensation causes lint,
dust and other airborne particles to cling to the glass
surface.
Also initial paint curing may deposit a slight film on
the glass. It is therefore recommended the glass be
cleaned two or three times with a non-ammonia based
household cleaner and warm water (gas fireplace glass
cleaner is recommended) within the first few weeks of
operation.
After the initial cleaning process the glass should be
cleaned two or three times during each operating
season depending on the environment in the house.
The use of any non-approved replacement glass will
void all product warranties.
Care must be taken to avoid breakage of the glass.
Do not operate appliance with glass front
removed, cracked or broken.
A replacement glass frame assembly (complete
with gasket) is available through your CFM
Corporation dealer and should only be installed
by a licensed qualified service person.
Operating Instructions
Glass Information
Glass Frame Assembly Removal
Glass Cleaning
Restrictor Plate Installation
Refer to Pages 17, 18 & 21 for your venting configura-
tion and combination of restrictor plate requirement and
fresh air restrictor plate adjustment.
Restrictor Plate Installation
Using the two (2) screws provided along with the restic-
tor plate shipped with the logset, fasten the restrictor
plate to the firebox top through the front of the unit. (Fig.
35)
Fresh Air Restrictor Plate Adjustment
1. Remove the glass.
2. Remove the logs, andirons and fettle.
3. Remove one side refractory (right or left) and re
-
move the rear upper and lower refractory in reverse
order of installation. (Refer to “Ceramic Refractory
Installation” section.)
4. Remove the rear log bracket by removing three (3)
screws. On some models you may be able to loosen
the screws and slide bracket to the left and out. (Fig.
36)
5. Adjust the fresh air restrictor plate setting. (Fig. 37)
Simultaneously install the plate and the log bracket
using the three (3) screws loosened or removed ear-
lier. The adjustment is made by matching the proper
setting on the plate with the three (3) holes on the
firebox back.
Phillips
Screws
FP1558a
Fig. 34 Remove Phillips screws, tilt frame forward and lift off
bottom door track. (Shown without logs for clarity.)










Clean the glass after the first two weeks of
operation.