21
Install the door control
1
Install the Door Control
Compatible with MyQ™ and Security✚
2.0™
accessories. NOTE: Older Chamberlain
accessories and third party products are not
compatible.
Your garage door opener is compatible with
up to 2 Security✚
2.0™ door controls.
Install the door control within sight of the
door at a minimum height of 5 feet (1.5 m)
where small children cannot reach, and away
from the moving parts of the door.
NOTE: Your product may look different than
the illustrations.
INTRODUCTION
To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is NOT connected BEFORE installing door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
• Install door control within sight of garage door, out of reach of children at a minimum
height of 5 feet (1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door control push buttons or remote
control transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no
obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to
cross path of closing garage door.
Screw
6ABx1-1/2" (2)
HARDWARE
Drywall
Anchors (2)
Screw
6-32x1" (2)
Screw
6ABx1-1/4" (2)
1.1 Strip 7/16 inch (11 mm) of
insulation from one end of the wire
and separate the wires.
7/16"
(11 mm)
1.2 Connect one wire to each of the
two screws on the back of the
door control. The wires can be
connected to either screw.
1.3 Mark the location of the bottom
mounting hole and drill a 5/32 inch
(4 mm) hole.
1.4 Install the bottom screw, allowing
1/8 inch (3 mm) to protrude from
the wall.
NOTE: For gang box installations it is not necessary to drill holes or install the drywall anchors. Use the existing holes in the gang box.
PRE-WIRED INSTALLATIONS: Choose any
two wires to connect, but make note of which
wires are used so that the correct wires are
connected to the garage door opener in a
later step.
6-32x1"
GANG BOX
DRYWALL
6ABx1-1/2"
Drywall Anchor