Chamberlain door opener Garage Door Opener User Manual


 
18
PROGRAMMING
SINGLE BUTTON CONTROL (SBC) REMOTE
This function programs a remote as a wireless single button
control. In B2 mode, operation is OPEN / STOP / CLOSE /
REVERSE / STOP. In C2 mode, operation is OPEN / STOP/
Constant pressure to CLOSE / STOP on release. There is no
operation in D1 mode. In T and TS modes, operation is OPEN /
STOP / CLOSE / REVERSE / STOP and Timer to Close
start/refresh. In FSTS mode, operation is OPEN with Timer to
Close start/refresh only bypassing all up mid stops. Momentary
and constant pressure commands are processed in this function.
1. Press and release the RADIO button on the logic board (LED
will light).
2. Press and release the SBC externally wired button or TIMER on
the logic board (LED flashes rapidly and then remains on
solid).
3. Press and hold the remote button until the LED flashes rapidly.
The LED will then remain on solid after releasing.
4. Press and release the RADIO button on the logic board (LED
flashes rapidly and then turns off). The programming mode is
exited if no activity is performed within 30 seconds.
ERASING REMOTES
Press and hold the RADIO button on the logic board until the
RADIO LED flashes rapidly (approximately 5 seconds).
All remotes will be erased.
Built in 3-channel, 315MHz radio receiver allows you to add as
many as 23 Security
®
remotes or dip switch remote controls.
PROGRAMMING REMOTES
STANDARD SINGLE BUTTON REMOTE
1. To enter programming press and release the RADIO button on
the logic board (LED will light).
2. Press and hold the remote button until the LED flashes rapidly,
then release remote button. The LED will then remain on solid
after releasing the button. Repeat to add additional remote(s).
3. Press and release the RADIO button to complete the
programming. The programming mode is exited if no activity is
performed within 30 seconds.
NOTE: Single button remote is not supported with D1 and E2
failsafe wiring modes.
NOTE: Requires self-monitoring photo eyes when using constant
pressure to close (wiring C2, D1 and E2 ).
OPERATION
MODE
B2
C2
D1
E2
T, TS
FSTS
OPEN STOP CLOSE Reverse
Constant
Pressure
Timer To
Close
To prevent possible SERIOUS INJURY or DEATH, install
reversing sensors when the 3-button control station is out of
sight of the door or ANY other control (automatic or manual) is
used. Reversing devices are recommended for ALL installations.
WARNING
CAUTION
WARNING
WARNING
L
i
f
t
M
a
s
t
e
r
U1
MRT
1RADIO
MID
2
TIM
E2
RELAY
RELAY
D1
C2
B2
OLS
MID
SLS
MOTOR
REV
CLS
D25
D24
D26
D27
D36
C77
C73
C54
C78
L1
L5
P6
D35
D16
P7
K3
FAILSAFE
X1
E1
R29
C11
D3
Ø
2
P4
Ø
14LG
Ø
65
C71
®
RADIO
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the
battery. THEREARE NO OTHERUSER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.