Chamberlain BG770 Home Security System User Manual


 
01-G1014 Field Wiring Diagram 32
Doc 01-G0674
Rev E
IT IS IMPORTANT TO READ ALL SAFETY RULES INCLUDED IN THE INSTALLATION MANUAL BEFORE
BEGINNING INSTALLATION. FAILURE TO COMPLY WITH THE SAFETY INSTRUCTIONS MAY RESULT
IN SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE.
NOTES:
1) REMOVE THIS JUMPER TO CAUSE GATEARM TO CLOSE IMMEDIATELY WHENEVER IT IS OPENED, UNLESS A VEHICLE IS ON THE
HOLD OPEN LOOP. IF THIS JUMPER IS NOT REMOVED, ARM WILL REMAIN OPEN UNTILA VEHICLE ENTERS AND EXITS THE HOLD
OPEN LOOP.
2) ADD JUMPER FROM TERMINAL #8 TO #9 WHENEVER CLOSE BUTTON IS USED. DO NOT USE WITH HOLD OPEN LOOP.
3) 115V UTILITY OUTLET (4 AMP MAX.) PROVIDED ON 115V MODELS ONLY.
4) SEE REVERSE SIDE FOR INTERNAL OPERATOR WIRING.
5) DO NOT CONNECT INPUT POWER LINES TO L1 & L2 TERMINALS. POWER LINES MUST BE CONNECTED TO THE POWER SWITCH.
DRAWING NO.:
01-G1014
FIELD WIRING
CONTROL WIRING
LOOP DETECTORS BY OTHERS
LINE VOLTAGE SUPPLY
RADIO CONTROL
MANUAL
OPEN
SEE
NOTE #1
SEE NOTE #2
SENSING EDGE
OPEN BUTTON
OR OTHER
OPEN CONTROL
CLOSE BUTTON
SEE NOTE #2
OPEN
LOOP
HOLD OPEN
LOOP
115V
ACCESSORIES
(0.2A MAX)
1 PHASE
INCOMING
LINE
LOOP WIRE CONNECTIONS FOR
FACTORY SUPPLIED (PLUG-IN)
DETECTORS ONLY
ELECTRICAL CABINET
ON
OFF
SWITCH
115V
OUTLET
SEE
NOTE #3
CONNECTIONS FOR LOOP
DETECTORS
NOT SUPPLIED BY THE FACTORY
PRESENCE CONTACT OF
LOOP
TO OPEN
PRESENCE CONTACT OF
LOOP T
O HOLD OPEN
LOOP
WIRES AND POWER FOR LOOP DETECTORS
SHOULD BE DIRECTLY WIRED TO DETECTOR ITSELF.
REFER TO INSTRUCTIONS ACCOMP
ANYING DETECTOR.
CONNECTIONS FOR STANDARD
3-WIRE 24 VAC RADIO CONTROL
RADIO CONTROL WILL OPEN GATE
AND REVERSE IF CLOSING. IT WILL
NOT STOP OR CLOSE THE GATE.
WARNING
(SEE NOTE #5)
(SEE NOTE #5)