Chamberlain 1200 Garage Door Opener User Manual


 
Adjustment Step 1
Adjust the UP and DOWN Limits
28
Limit adjustment settings regulate the points at
which the door will
stop
when moving up or down.
The door will
stop
in the
up
direction if anything
interferes with door travel. The door will
reverse
in
the
down
direction if anything interferes with the
door travel (including binding or unbalanced doors).
To operate the opener, press the Door Control
button/push bar. Run the opener through a
complete travel cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse
unintentionally when fully closed?
If your door passes both of these tests, no limit
adjustments are necessary.
Left Side
Panel
INCREASE TRAVEL
DOWN
UP
Adjustment Label
Limit
Adjustment
Screws
INCREASE TRAVEL
DOWN
UP
Adjustment procedures are outlined below. Run the opener through a complete travel cycle after each
adjustment.
Repeated operation of the opener during adjustment procedures may cause the motor to overheat and
shut off. Simply wait 15 minutes and try again.
Read the procedures carefully before continuing on to Adjustment Step 2. Use a screwdriver to make limit
adjustments.
How and When to Adjust the Limits
If the door does not
open completely
but opens
at least
five feet
Increase
up
travel. Turn the UP limit adjustment
screw clockwise. One turn equals 2" of travel.
If door does not open at least 5 feet:
Adjust the UP (open) force as explained in
Adjustment Step 2.
If the door does not
close completely
Increase
down
travel. Turn the DOWN limit
adjustment screw counterclockwise. One turn
equals 2" of travel.
If door still won't close completely, try lengthening
the door arm. (See page 26.)
If you have adjusted the door arm to the maximum
length and the door still will not close completely,
lower the header bracket. See Installation Step 1,
pages 12 and 13.
If the opener
reverses
in fully closed position
Decrease
down
travel. Turn the DOWN limit
adjustment screw clockwise. One turn equals 2"
of travel.
If the door
reverses
when closing and
there is no visible interference to travel cycle
If the opener lights are flashing, the Safety Reversing
Sensor is obstructed. Remove the obstruction.
Test the door for binding: Pull the manual release
handle. Manually open and close the door. If the door
is binding, call for garage door service. If the door is
not binding or unbalanced, adjust the DOWN (close)
force. See Adjustment Step 2.
Adjustment Section: Pages 28 – 30
Improper adjustment of the travel limits will
interfere with the proper operation of the safety
reverse system.
The door might not reverse
when required and could seriously injure or kill
someone under it.
Test the safety reverse
system following all adjustments to the travel
limits. See page 30.
WARNING