Vermont Casting IRFSDV34 Indoor Fireplace User Manual


 
22
Irving Oil
10004000
1. STOP! Read the safety information above on
this page.
2.
Turn off all electrical power to the fireplace appliance.
3.For MN/MP/TN/TP appliances only, go on to
Step 4. for RN/RP turn the On/Off switch to “OFF”
position or set thermostat to lowest level.
4.Open control access panel.
5.Push in gas control knob slightly and turn
clockwise to “OFF”. Do not force.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A. This fireplace has a pilot which must be lit manually.
When lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the fireplace
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly
depressing the piezo spark ignitor until a flame
appears. Continue to hold the control knob in for
about one (1) minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5 through 8.
1. Turn the On/Off switch to “OFF” or set the
thermostat to lowest setting.
2. Turn off all electric power to the fireplace if service
is to be performed.
• If you cannot reach your gas supplier, call
the Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualified service technician. Applying force or any
attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service
technician to inspect the fireplace and to replace
any part of the control system and any gas control
which has been under water.
3. Open control access panel.
4. Push in gas control knob slightly and turn
clockwise to “OFF”. Do not force.
5. Close control access panel.
If knob does not pop up when released, stop
and immediately call your service technician or
gas supplier.
If after several tries, the pilot will not stay lit, turn
the gas control knob to “OFF” and call your
service technician or gas supplier.
11. Replace window fram assembly.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the ON/OFF switch to
“ON” position or set themostat to desired setting.
14. Turn on all electrial power to the fireplace.
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING AND OPERATING INSTRUCTIONS
LIGHTING INSTRUCTIONS
EURO SIT SIT NOVA HONEYWELL
6. Wait (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas ,
STOP! Follow “B” in the safety information above
this page. If you don’t smell gas, go to the next step.
7. Remove window fram assembly glass door before
lighting pilot.
(See Glass Frame Removal in manual).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counter clockwise
to “PILOT”.
TO TURN OFF GAS FIREPLACE
PILOT
ON
OFF
ON
P
I
L
O
T
O
F
F
O
F
F
HI
OFF
PILOT
LO