Vermont Casting DVRT43 Indoor Fireplace User Manual


 
28
Vermont Castings, Majestic Products DVRT36/39/43
10002428
NOTE: Glowing lava rock for DVRT36, DVRT39 and
DVRT43 is only allowed to be positioned at the
front area (radiant portion) of the burner housing
assembly.
Inspecting the Venting System
This appliance venting system is designed and
constructed to develop a positive flow adequate to
remove flue gases to the outside atmosphere.
Any foreign objects in the venting system, except those
designed specifically for the venting system, may cause
spillage of flue gases.
To inspect the venting system, make sure the main gas
valve is off. Remove the window frame assembly.
(Refer to Window Frame Assembly Removal section.)
Using a flashlight, check the area above the baffle in
the combustion dome. Clean if necessary.
Glowing Lava Rock
LG231
Fig. 51 Correct burner flame appearance for DVRT43.
5 Flame areas
Glowing Lava Rock
LG230
Fig. 50 Correct burner flame appearance for DVRT39.
5 Separate flames
Glowing Lava Rock
LG229
Fig. 49 Correct burner flame appearance for DVRT36.
3/8" - 1/2"
Fig. 48 Correct pilot flame appearance.
PSE Pilot
SIT Pilot
3/8"-1/2"
Electronic
Ignition
F584-703/
FP1370