8. Place the right front log (G5) in position on the
ember lava rock. Use the notches under the log front
right to have a proper location.
LG324
BREF42 logs
1/04
G2
G1
G4
G3
G5
LG324
Fig. 7 BREF42/BREF42R ceramic log placement.
To reduce the risk of fire, electrical shock
or personal injury, disconnect all power
coming to the fireplace at the main service
panel before attempting any maintenance
or cleaning.
Replacing Light Bulbs
This fireplace uses four (4) clear, 120 Volt, 60 Watt,
E-12 socket base (small base, chandelier candle-type)
light bulbs. These lights are located under the ember
bed of the unit.
Do not exceed 60 Watts per bulb. Use of
higher-rated bulbs may result in fire, caus-
ing property damage, personal injury, or
loss of life.
NOTE: For the sake of convenience, you may wish
to consider replacing all the light bulbs if one of
them burns out.
1. Turn OFF the power to the unit at the main service
panel.
2. If the fireplace has been operating, allow it to cool.
3. Open glass (if applicable); open steel curtain.
4. Remove the log. Remove the two (2) screws, one
on each side of the ember bed/plate support log set
down. Remove the ember bed/plate support log set.
5. Examine the bulbs to determine which one(s) need
to be replaced (if you are not going to replace all).
7. Install new light bulb(s) by screwing in while holding
the socket.
8. Reinstall the ember bed, log set, glass door, and
steel curtain.
Cleaning Trim
Clean the trim using a soft cloth you have slightly damp-
ened with lemon oil; then buff with a clean soft cloth.
NOTE: You can obtain lemon oil at super-markets
and hardware stores. Do not use commercially
made brass polish or household cleaners, as these