2828
Radiance Direct Vent/Natural Vent Gas Heater
20004188
Light pilot burner
Set manual switch
to local or remote
Release pilotstat
knob.
Turn pilotstat knob
from PILOT to ON.
If manual switch is
set to LOCAL, did
main burner light
and fan turn on?
Turn pilotstat knob
to PILOT to turn
off main burner.
Turn pilotstat knob
to OFF to turn
valve completely
off.
Comfort Valve System Control Sequence Of Operation With Transmitter
Did the LED stop
blinking?
Review LED fail-
ure analysis.
Five minute wait
period
Cycle switch
once and leave in
remote. Press any
key on transmit-
ter for recognition
operation.
Local Path
Move switch from
local to remote.
Press any key on
transmitter. Move
switch back to
local.
Yes
If the manual switch
is set to REMOTE,
press the mode but-
ton to display “ON”.
does transmitter con-
trol the main burner
and fan?
Does transmitter
change levels of
flame height, fan
speed?
Set levels of flame
height and fan to
“0” to shut off main
burner and fan.
Turn pilotstat knob
to OFF to turn
valve completely
off.
On Path
Move switch from
manual to remote.
Press any key on
transmitter.
Yes
Yes
No
Choose Manual or
Remote path. Set
switch to manual or
remote.
Yes
No