16
Defiant Woodburning Stove
30001693
Distance from the Center of the Flue Collar to the Wall
The information on this page is helpful in planning stove placement, particularly in those installations with
chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must
adhere to the guidelines in the clearance chart on Page 12.
Note that rear dimensions differ for installations with 6” or 8” chimney connectors.
Defiant With Rear Heat Shield only
Unprotected Surfaces
Protected Surfaces
Parallel Installations
Corner
Installations
Corner
Installations
Parallel Installations
Defiant With Rear Heat Shield and Shielded Connector:
Defiant With Rear Heat Shield and Double-wall Connector:
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
39
¹⁄₂” (1003mm) 6” chimney: 28” (710 mm) 29¹⁄₂” (710 mm) 6” chimney: 25” (635 mm)
27” (685 mm) 21” (535 mm)
8” chimney: 8” chimney:
28” (710 mm) 22” (560 mm)
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
39
¹⁄₂” (1003mm) 6” chimney: 28” (710 mm) 29¹⁄₂” (710 mm) 6” chimney: 25” (635 mm)
17” (432 mm) 17” (432 mm)
8” chimney: 8” chimney:
18” (457 mm) 18” (457 mm)
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
39
¹⁄₂” (1003mm) 6” chimney: 28” (710 mm) 29¹⁄₂” (710 mm) 6” chimney: 25” (635 mm)
17” (432 mm) 15” (381 mm)
8” chimney: 8” chimney:
18” (457 mm) 16” (406 mm)
ST511
Intrepid
flue centerline
Diagrams
11/16/00
*
A
B
C
*
D
E
F
* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this
page: 34” (865 mm) in the United States and 36” (914 mm) in Canada.