Carrier GT-G Heat Pump User Manual


 
Indoor & Outdoor Split
Geothermal Comfort Systems
Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05
15
ARI/ISO/ASHRAE 13256-1
GT-GS (50YCS) & GT-S (38WQS) Performance Data - English (IP) Units
GT-GS (50YCS) & GT-S (38WQS) Performance Data - Metric (SI) Units
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature.
Heating capacities based upon 68°F DB, 59°F WB entering air temperature.
All ratings based upon 208V operation.
Model
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 30°C Heating 20°C Cooling 15°C Heating 10°C Cooling 25°C Heating 0°C
Capacity
Watts
EER
W/W
Capacity
Watts
COP
Capacity
Watts
EER
W/W
Capacity
Watts
COP
Capacity
Watts
EER
W/W
Capacity
Watts
COP
018 4,865 4.2 5,950 4.8 5,422 6.5 4,543 4.0 5,217 4.7 3,751 3.5
024 6,887 4.2 8,587 4.7 7,532 6.0 6,682 3.9 7.386 4.9 5,451 3.5
030 8,206 4.3 9,965 4.7 8,851 6.1 7,737 3.9 8.734 4.8 6,301 3.5
036 9,613 4.2 11,489 4.4 10,229 5.9 9,349 3.9 10,170 4.7 7,591 3.3
042 11,665 4.1 14,156 4.7 12,925 5.8 11,079 3.9 12,309 4.5 9,291 3.6
048 13,042 4.2 15,387 4.8 13,921 5.7 12,309 3.9 13,892 4.7 10,492 3.6
060 16,149 3.8 21,307 4.6 16,940 5.0 16,735 3.7 16,882 4.2 13,834 3.5
Model
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86°F Heating 68°F Cooling 59°F Heating 50°F Cooling 77°F Heating 32°F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
018 16,600 14.4 20,300 4.8 18,500 22.1 15,500 4.0 17,800 16.2 12,800 3.5
024 23,500 14.5 29,300 4.7 25,700 20.6 22,800 3.9 25,200 16.6 18,600 3.5
030 28,000 14.7 34,000 4.7 30,200 20.8 26,400 3.9 29,800 16.4 21,500 3.5
036 32,800 14.5 39,200 4.4 34,900 20.1 31,900 3.9 34,700 15.9 25,900 3.3
042 39,800 14.1 48,300 4.7 44,100 19.7 37,800 3.9 42,000 15.5 31,700 3.6
048 44,500 14.2 52,500 4.8 47,500 19.3 42,000 3.9 47,400 15.9 35,800 3.6
060 55,100 13.0 72,700 4.6 57,800 17.2 57,100 3.7 57,600 14.2 47,200 3.5
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature.
Heating capacities based upon 68°F DB, 59°F WB entering air temperature.
All ratings based upon 208V operation.