PHYSICAL DATA
Physical Data--Unit 50XP
UNITSIZE 024 030 036 042 048 060
NOMINAL CAPACITY (ton) 2 2---1/2 3 3---1/2 4 5
SHIPPING WEIGHT (lb)
SHIPPING WEIGHT (kg)
356
161
360
163
378
171
436
198
470
213
515
234
COMPRESSORS
Quantity
Scroll
1
REFRIGERANT (R---410A)
Quantity (lb.)
Quantity (kg)
7.3
3.3
8.0
3.6
9.5
4.3
10.7
4.9
11.25
5.1
13.2
6.0
REFRIGERANT METERING DEVICE TXV
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
2...21
11.95
2...21
12.0
2...21
13.6
2...21
15.4
2...21
17.4
2...21
19.3
OUTDOOR FAN
Nominal Cfm
Diameter (in.)
Diameter (mm)
Motor Hp (Rpm)
2350
22
558.8
1/8 (825)
2700
22
558.8
1/8 (825)
2350
22
558.8
1/8 (825)
2800
22
558.8
1/8 (825)
3300
22
558.8
1/4 (1100)
3300
22
558.8
1/4 (1100)
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
3...15
3.7
3...15
3.7
4...15
3.7
3...15
4.7
4...15
4.7
4...17
5.7
INDOOR BLOWER
Nominal Cooling Airflow (Cfm)
Size(in.)
Size (mm.)
Motor HP (RPM)
800
10x10
254x254
1/2 (1050)
1000
10x10
254x254
1/2 (1050)
1100
11x10
279.4x254
3/4 (1000)
1400
11x10
279.4x254
3/4 (1075)
1400 1750
11x10
279.4x254
11x10
279.4x254
3/4 (1075) 1.0 (1040)
HIGH---PRESSURE SWITCH
(psig)Cut---out Reset(Auto)
650 +/--- 15
420 +/--- 25
LOSS --- OF --- CHARGE / LOW --- PRESSURE
SWITCH (Liquid Line) (psig) cut---out Re-
set (auto)
20 +/--- 5
45 +/--- 10
RETURN ---AIR FILTERS}
Throwaway Size (in.)
Throwaway Size (mm)
20x20x1
508x508x25
20x24x1
508x610x25
24x30x1
610x762x25
{ Required filter sizes shown are based on the larger of the AR I(Air Conditioningand Refrigeration Institute) rated cooling airflow or the heating airflowvelocity
of 300 ft/minute for throwaway type or 450 ft/minute for high---capacity type. Air filter pressure dropfor non---standardfiltersmust not exceed0.08 IN. W.C..
} If usingaccessory filterrack refer tothe filter rackinstallation instructionsfor correct filter sizes and quantity.
50XP