Carrier 50XP Air Conditioner User Manual


 
4
ARI* CAPACITIES
Cooling Capacities and Efficiencies
UNIT 50XP NOMINAL TONS STANDARD CFM
NET COOLING
CAPACITIES (Btuh)
EER** SEER†
024 2 770 24,000 11.0 13.2
030 2--1/2 960 29,000 11.0 13.0
036 3 1100 36,000 11.2 13.5
042 3--1/2 1450 41,000 11.2 13.0
048 4 1450 45, 000 11.0 13.0
060 5 1710 57, 000 11.0 13.0
LEGEND
dB --- Sound Levels(decibels)
db—Dry Bulb
SEER—Seasonal Energy Efficiency Ratio
wb—WetBulb
COP---Coefficient of Performance
* Air Conditioning & Refrigeration Institute.
**At “A” conditions---80_F (26.7_C) indoor db/67_F (19.4_C) indoor wb &
95_F(35_C ) outdoordb.
{ Rated in accordance with U.S. Government DOE Department of Energy)
testprocedures and/or ARI Standards 210/240.
Notes:
1. Ratingsare netvalues, reflectingthe effectsof circulating fan heat.
Ratingsare based on:
Cooling Standard:80°F (26.7_C) db, 67°F wb(19.4_C) indoor entering ---air
temperatureand 95°Fdb(35_C) outdoor entering---ai r temperature.
2. Before purchasingthisappliance, readimportantenergycostand effi-
ciency information available from your retailer.
A--Weighted Sound Power (dBA)
50XP
STANDARD
RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment)
125 250 500 1000 2000 4000 8000
024 72 58.8 63.5 67.2 66.9 63.7 58.3 50.0
030 72 58.8 63.5 67.2 66.9 63.7 58.3 50.0
036 72 60.7 63.3 66.8 66.5 64.2 60.3 53.0
042 72 56.7 62.8 67.8 67.4 63.7 57.7 50.8
048 78 62.4 69.9 71.3 73.4 70.0 66.3 60.1
060 78 63.5 67.6 71.8 75.5 71.0 68.1 59.9
* Tested in accordance with ARI Standard 270 (not listed in ARI).
50XP