Canon Vb-C50fi Home Security System User Manual


 
3-6
Ethernet
1
2
Note
Contact the network administrator for the IP address, subnet mask and default
gateway address settings.
Take particular care with the IP address, subnet mask, default gateway address
and route settings. If errors are found in any of these items, you may be completely
unable to access the VB-C50Fi via Ethernet and it may only be possible to recover
the problem by using the Initial Setup Tool (P.2-7) to correct the error.
3
4
5
Setting Up the Administrator Password and Ethernet etc. (System and Network)
1 “Address Setting Method”
Select an address setting method from “Auto Setting (DHCP)” or “Manual Setting”. If you select
“Auto Setting (DHCP)”, you can use the values automatically obtained from the DHCP server
for “IP Address”, “Subnet Mask” and “Default Gateway Address”. If you select “Manual Setting”,
directly enter values which suit your environment.
2 “IP Address”
Enter a network interface-specific IP address.
3 “Subnet Mask”
Enter the subnet mask specified for the network to be connected.
4 “Default Gateway Address”
Set this item when you want to connect to a different segment within the Intranet or a wide area
network such as the Internet.
5 “Maximum Transmission Unit”
Enter the maximum transmission unit size to be sent at one time. There is normally no need to
change this from 1500.
If you are using ADSL, you may experience increased data transmission efficiency if you slightly