New Buck Corporation 21 Stove User Manual


 
OUT SIDE AIR INSTALLATION
1. Select an installation location that will give the best airflow from the front of the heater
to the remainder of the home.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR MUST BE MAIN-
TAINED. (MOVE OPENING AND/OR REPOSITION HEATER LOCATION IF
NECESSARY).
2. Place the protective floor pad in position. For minim floor protection
(See Pages 23, 25).
3. Place the unit on the pad making sure the minimumum clearance specifications are met.
4. Lightly mark with a pencil the location of the pedestal on the protective pad.
5. Next, remove the four (4) screws holding the heater to the stand. Position heater out of the
way of the installation area.
6. Check that the pedestal stand is still aligned with the marks on the protective pad, now mark
the outside air opening in bottom of pedestal stand on to the pad.
7. Next, mark the hole for the outside air opening. Set stand aside for now.
8. Next, cut a 4 1/4" diameter hole in the pad and continue through the floor.
9. Now, reposition the pedestal stand and set on the pad being sure to line the stand up with
the reference marks.
10. Using an electric drill and 3/8" masonry bit, drill four (4) holes in the protective pad using
the holes in the bottom side lips of the pedestal stand as a guide. Be careful to drill only
through the pad and not into the floor. Change the bit to a 1/4" metal bit and drill through
the floor.
11. Using the four (4) 3/8" x 1-1/2" lag bolts provided, secure the pedestal stand and pad to
the floor of the mobile home.
CAUTION
IF A THICK FLOOR PROTECTOR IS USED, YOU MAY HAVE TO USE LONGER
LAG BOLTS.
12. Set the heater back onto the stand and resecure using the screws.
13. Obtain the outside air duct from the box in the pedestal kit marked FA P21B.
26