New Buck Corporation 21 Stove User Manual


 
A. Vertical exit using
(6" Single Wall minimum 24 ga. blued or black
pipe,
and any listed 2100° UL 103 HT. TYPE Chimney).
Without optional close clearance shield, and pipe shield.
Model 21 minimum clearance to combustibles.
NOTE: All clearances are to combustibles without close clearance shields, and pipe shield, using 6"
Single Wall minimum 24 ga. blued or black pipe , and minimum floor protector . The clearances
above may be reduced. Follow NFPA-211 codes if available or follow instructions on (Pages 18,
and 19, or Pages 22, and 23).
A B C D E F G
MODEL 21 25”
13" 19" 15.5" 8" 3" 16"
C
C
C
C
Figure 7.
BACK
WALL
A
E
B
F
D
G
A
E
B
D
F
BACK WALL
SIDE WALL
PROTECTOR
G
Figure 8.
SINGLE WALL
CONNECTOR PIPE
CEILING SUPPORT
CEILING
INSTALLATION
FLASHING
CONTEMPORARY CAP
STORM COLLAR
DO NOT OBSTRUCT
CAULK
NEW BUCK
SIDE
WALL
BUCK STOVE
LISTED 2100° UL 103 HT
TYP. CHIMNEY
RADIATION SHIELD
LISTED 2100° UL 103 HT TYP.
15