SPECIFICATIONS
See notes on page 5.
UNIT SIZE-SERIES
018-B 024-B 030-B 036-B 042-B
Operating Weight (Lb) 198 198 221 211 231
ELECTRICAL
Unit Volts-Hertz-Phase 208/230-60-1
Operating Voltage Range 187—253
Unit Ampacity for Wire Sizing 16.1 17.5 18.7 21.0 32.0
Min Wire Size (60
°
C/75
°
C Copper) (AWG)* 14/14 14/14 14/14 12/12 8/10
Maximum Length (60
°
C/75
°
C) (Ft)** 46/44 44/42 41/39 60/57 97/59
Max. Branch Circuit Fuse Size (Amps)‡ 25 25 30 30 50
Compressor Rated Load Amps 12.5 13.6 14.2 16.0 24.9
Locked Rotor Amps 47.0 61.0 72.5 88.0 104.0
Fan Motor HP and RPM 1/15 and 820 1/15 and 820 1/8 and 820 1/8 and 820 1/8 and 820
Full Load Amps 1.0 1.0 1.0 1.0 1.0
COMPRESSOR AND REFRIGERANT
Compressor Type Scroll
Refrigerant—Type and Amount (Lb)† R-22 and 5.63 R-22 and 8.88 R-22 and 7.13 R-22 and 10.88
OUTDOOR COIL AND FAN
Coil Face Area (Sq Ft) 15.15
Rated Airflow (CFM) 2500 2400 2900
OPTIONAL EQUIPMENT
Support Feet Kit—4 In. (4) KSASF0101AAA
Snow Stand—18 In. KHASS0206MPK
Time-Delay Relay KAATD0101TDR
Interface Control‡‡‡ KHAIC0101AAA
Service Alarm KHASA0101AAA††
Outdoor Thermostat KHAOT0301FST
Secondary Outdoor Thermostat KHAOT0201SEC
Cycle Protector Standard
Crankcase Heater KAACH1201AAA
Start Assist—PTC KAACS0201PTC
Start Capacitor and Relay KSAHS1501AAA
Sound Hood Standard
TXV Kits (Hard Shutoff) KHATX0901HSO KHATX1001HSO KHATX1101HSO KHATX1201HSO
TXV Kits (RPB) N/A
Low-Pressure Switch Standard
High-Pressure Switch Standard
Evaporator Freeze Thermostat KAAFT0101AAA‡‡
Isolation Relay KHAIR0101AAA‡‡
Liquid Solenoid Valve KHALS0101LLS
Filter Drier—Bi-flow P504-8083S (RCD) P504-8163S (RCD)
Low-Ambient Controller P251-0083(RCD)
MotorMaster® Control 32LT660004***
Ball Bearing Fan Motor HC38GE230 (RCD)
Thermostat, Auto Changeover,
Non-Programmable,
°
F/
°
C,
2-Stage Heat, 1-Stage Cool TSTATBHNHP01-A
Thermostat, Auto Changeover,
7-Day Programmable,
°
F/
°
C,
2-Stage Heat, 1-Stage Cool TSTATBHPHP01-A
Thermostat, Manual Changeover,
Non-Programmable,
°
F,
2-Stage Heat, 1-Stage Cool HH07AT214
Thermostat, Auto Changeover,
Non-Programmable,
°
F/
°
C,
Dual Fuel Thermostat. Must be used with
Outdoor Sensor (TSTATBBSEN01) TSTATBHPDF01-A†††
Outdoor Sensor TSTATBBSEN01