Bryant 697C Heat Pump User Manual


 
—34—
HEAT PUMP HEATING PERFORMANCE Continued
* The Btuh heating capacity values shown are net “integrated’’ values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB—Entering Dry Bulb
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
3 7 1727374757
EDB CFM
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
697C060-A Outdoor Section With FK4CNB006 Indoor Section
65
1575 28.0 25.8 3.81 33.2 30.6 4.02 39.1 35.6 4.24 45.3 40.3 4.4 52.8 48.0 4.81 61.2 61.2 5.20 71.0 71.0 5.73
1750 28.3 26.0 3.82 33.5 30.8 4.01 39.4 35.9 4.22 45.7 40.5 4.4 53.2 48.4 4.76 61.7 61.7 5.14 71.7 71.7 5.65
2012 28.6 26.3 3.84 33.9 31.1 4.02 39.7 36.2 4.21 46.1 40.9 4.4 53.7 48.9 4.72 62.3 62.3 5.09 72.0 72.0 5.52
70
1575 27.7 25.5 3.98 32.9 30.3 4.21 38.7 35.3 4.45 44.9 39.8 4.7 52.1 47.5 5.05 60.5 60.5 5.45 70.2 70.2 5.99
1750 28.0 25.7 3.99 33.2 30.5 4.20 39.0 35.6 4.43 45.2 40.1 4.6 52.6 47.8 4.99 61.0 61.0 5.38 71.6 71.6 5.91
2012 28.3 26.0 4.02 33.5 30.8 4.21 39.4 35.9 4.42 45.6 40.5 4.6 53.1 48.3 4.95 61.6 61.6 5.32 71.5 71.5 5.84
75
1575 27.4 25.2 4.16 32.6 30.0 4.41 38.3 35.0 4.67 44.4 39.4 4.9 51.6 47.0 5.29 59.8 59.8 5.72 69.3 69.3 6.27
1750 27.6 25.4 4.16 32.9 30.2 4.40 38.6 35.2 4.64 44.7 39.7 4.9 52.0 47.3 5.23 60.3 60.3 5.64 70.0 70.0 6.17
2012 28.0 25.7 4.19 33.2 30.5 4.41 39.0 35.6 4.63 45.2 40.1 4.8 52.5 47.8 5.18 60.9 60.9 5.57 70.7 70.7 6.10
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Heating
Indoor
Section Size
Heating
Capacity Power Capacity Power
F(A,B)4AN(F,B,C) 060 1.00 1.09 CD3(A,B)A 060 1.00 1.17
FB4ANB 070 1.00 1.03 CE3AA 060 1.00 1.10
FC4BN(F,B) 060 1.00 1.09 CJ5A/CK5A/CK5BA 060 1.00 1.12
FC4BNB 070 1.00 1.03 CK5A/CK5A/CK5BX 060 1.00 1.06
FG3AAA 060 1.00 1.13 CK3BA 060 1.00 1.12
FK4BNB 006 1.00 1.01
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
FK4CNB 006 1.00 1.00 CC5A/CD5A/CD5BA 060 1.00 1.19
CC5A/CD5A/CD5BA 060 1.00 1.18 CC5A/CD5A/CD5BW 060 1.00 1.10
CC5A/CD5A/CD5BW 060 1.00 1.11 CD3(A,B)A 060 1.00 1.19
CD3(A,B)A 060 1.00 1.18 CE3AA 060 1.00 1.11
CE3AA 060 1.00 1.11 CJ5A/CK5A/CK5BA 060 1.00 1.11
CJ5A/CK5A/CK5BA 060 1.00 1.12 CK5A/CK5A/CK5BX 060 1.00 1.06
CJ5A/CK5A/CK5BN 060 1.00 1.12 CK3BA 060 1.00 1.11
CJ5A/CK5A/CK5BX 060 1.00 1.07
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CK3BA 060 1.00 1.12 CC5A/CD5A/CD5BA 060 1.00 1.19
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE CC5A/CD5A/CD5BW 060 1.00 1.11
CC5A/CD5A/CD5BA 060 1.00 1.17 CD3(A,B)A 060 1.00 1.19
CC5A/CD5A/CD5BW 060 1.00 1.10