Bryant 697C Heat Pump User Manual


 
—31—
HEAT PUMP HEATING PERFORMANCE Continued
See notes on page 34.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
3 7 1727374757
EDB CFM
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
697C036-B Outdoor Section With FC4BN(F,B)042 Indoor Section Continued
65
1100 16.0 14.7 2.43 19.3 17.7 2.53 22.8 20.8 2.64 26.7 23.7 2.74 31.2 28.4 2.87 36.1 36.1 3.03 41.8 41.8 3.23
1200 16.2 14.9 2.46 19.4 17.9 2.55 23.0 21.0 2.65 26.9 23.9 2.75 31.4 28.6 2.87 36.4 36.4 3.03 42.1 42.1 3.22
1300 16.4 15.1 2.48 19.7 18.1 2.58 23.2 21.1 2.66 27.1 24.1 2.76 31.6 28.7 2.88 36.6 36.6 3.03 42.4 42.4 3.22
70
1100 15.7 14.5 2.52 19.1 17.5 2.64 22.6 20.6 2.75 26.5 23.5 2.87 30.9 28.1 3.00 35.7 35.7 3.17 41.3 41.3 3.37
1200 15.9 14.6 2.55 19.2 17.7 2.66 22.8 20.8 2.76 26.7 23.7 2.87 31.1 28.3 3.00 36.0 36.0 3.16 41.6 41.6 3.36
1300 16.1 14.8 2.57 19.4 17.8 2.68 23.0 20.9 2.78 26.9 23.9 2.88 31.3 28.5 3.01 36.2 36.2 3.16 41.9 41.9 3.35
75
1100 15.4 14.1 2.62 18.9 17.3 2.74 22.4 20.4 2.87 26.2 23.3 2.99 30.6 27.8 3.14 35.4 35.4 3.31 40.9 40.9 3.52
1200 15.6 14.3 2.64 19.0 17.5 2.76 22.6 20.6 2.88 26.4 23.5 3.00 30.8 28.0 3.14 35.6 35.6 3.30 41.2 41.2 3.50
1300 15.7 14.5 2.67 19.2 17.6 2.78 22.7 20.7 2.89 26.6 23.6 3.01 31.0 28.2 3.14 35.9 35.9 3.30 41.5 41.5 3.50
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Heating
Indoor
Section Size
Heating
Capacity Power Capacity Power
COILS + 355MAV060100 VARIABLE-SPEED FURNACE COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA 042 0.99 0.97 CJ5A/CK5A/CK5BA 042 0.99 0.95
CD3(A,B)A 042 0.99 0.97 CJ5A/CK5A/CK5BW 036 0.99 0.95
CJ5A/CK5A/CK5BA 042 0.99 0.95 CK3BA 036 0.99 0.95
CJ5A/CK5A/CK5BW 036 1.00 0.96 042 0.99 0.95
CK3BA 036 1.00 0.96
042 0.99 0.95