Bryant 650A Heat Pump User Manual


 
—9—
COMBINATION RATINGS Continued
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard:
80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the
394HAD.
†† Indoor Airflow
COP
— Coefficient of Performance
EER
— Energy Efficiency Ratio
HSPF
— Heating Seasonal Performance Factor
SEER
— Seasonal Energy Efficiency Ratio
TC
— Total Capacity (Btuh)
TDR
— Time-Delay Relay
TXV
— Thermostatic Expansion Valve
UNIT
SIZE-
SERIES
INDOOR
UNIT CFM††
ARI STANDARD RATINGS*
Cooling Heating
TC
Seasonal Efficiency SEER
EER
High-Temp Low-Temp
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
Puron
TXV
Puron TXV
& TDR** TC COP TC COP
048-A,C
CJ5A/CK5A/CK5BA060 1400 45,000 NONE 12.50 10.75 48,000 3.50 28,600 2.38 8.20
CJ5A/CK5A/CK5BN060 1400 45,500 NONE 13.00 10.90 48,500 3.52 28,600 2.38 8.25
CJ5A/CK5A/CK5BX060 1400 45,500 NONE 13.00 10.90 48,500 3.52 28,600 2.38 8.25
CK3BA060 1400 45,000 NONE 12.50 10.75 48,000 3.50 28,600 2.38 8.20
060-B,C
FV4ANB006† 1750 58,000 TDR&TXV 13.00 10.75 60,000 3.56 37,000 2.54 8.00
FB4ANB070 1750 57,000 TDR 12.00 10.20 60,000 3.44 37,800 2.46 7.80
FC4BNB070 1750 57,000 TDR 12.00 10.20 60,000 3.44 37,800 2.46 7.80
FK4CNB006 1750 58,000 TDR 12.80 10.75 59,500 3.56 37,000 2.54 8.00
FX4ANB060 1750 57,000 TDR&TXV 12.00 10.20 60,000 3.44 37,800 2.46 7.80
CC5A/CD5AW060 1750 56,000 NONE 12.50 10.45 58,500 3.26 36,800 2.42 7.50
CJ5A/CK5A/CK5BX060 1750 56,500 NONE 12.50 10.55 59,000 3.44 37,000 2.50 7.70