—9—
COMBINATION RATINGS Continued
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard:
80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the
394HAD.
†† Indoor Airflow
COP
— Coefficient of Performance
EER
— Energy Efficiency Ratio
HSPF
— Heating Seasonal Performance Factor
SEER
— Seasonal Energy Efficiency Ratio
TC
— Total Capacity (Btuh)
TDR
— Time-Delay Relay
TXV
— Thermostatic Expansion Valve
UNIT
SIZE-
SERIES
INDOOR
UNIT CFM††
ARI STANDARD RATINGS*
Cooling Heating
TC
Seasonal Efficiency SEER
EER
High-Temp Low-Temp
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
Puron
TXV
Puron TXV
& TDR** TC COP TC COP
048-A,C
CJ5A/CK5A/CK5BA060 1400 45,000 NONE — — 12.50 10.75 48,000 3.50 28,600 2.38 8.20
CJ5A/CK5A/CK5BN060 1400 45,500 NONE — — 13.00 10.90 48,500 3.52 28,600 2.38 8.25
CJ5A/CK5A/CK5BX060 1400 45,500 NONE — — 13.00 10.90 48,500 3.52 28,600 2.38 8.25
CK3BA060 1400 45,000 NONE — — 12.50 10.75 48,000 3.50 28,600 2.38 8.20
060-B,C
FV4ANB006† 1750 58,000 TDR&TXV 13.00 — — 10.75 60,000 3.56 37,000 2.54 8.00
FB4ANB070 1750 57,000 TDR — 12.00 — 10.20 60,000 3.44 37,800 2.46 7.80
FC4BNB070 1750 57,000 TDR — 12.00 — 10.20 60,000 3.44 37,800 2.46 7.80
FK4CNB006 1750 58,000 TDR — 12.80 — 10.75 59,500 3.56 37,000 2.54 8.00
FX4ANB060 1750 57,000 TDR&TXV 12.00 — — 10.20 60,000 3.44 37,800 2.46 7.80
CC5A/CD5AW060 1750 56,000 NONE — — 12.50 10.45 58,500 3.26 36,800 2.42 7.50