Bryant 650A Heat Pump User Manual


 
—16—
HEAT PUMP HEATING PERFORMANCE Continued
See notes on page 17.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
3 7 172737475767
EDB CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section
65
1125 14.7 13.5 2.42 18.3 16.8 2.51 21.9 20.0 2.59 25.8 22.9 2.66 30.4 27.6 2.76 35.6 35.6 2.88 41.7 41.7 3.04 48.8 48.8 3.27
1250 14.9 13.7 2.45 18.5 17.0 2.53 22.9 20.9 2.61 26.1 23.2 2.67 30.7 27.9 2.76 35.9 35.9 2.87 42.1 42.1 3.03 49.3 49.3 3.25
1375 15.1 13.9 2.49 18.7 17.2 2.56 22.4 20.4 2.62 26.3 23.4 2.68 31.0 28.2 2.76 36.3 36.3 2.87 42.5 42.5 3.03 49.7 49.7 3.25
70
1125 14.1 13.0 2.51 17.9 16.4 2.61 21.6 19.7 2.70 25.4 22.6 2.79 29.9 27.2 2.89 35.0 35.0 3.02 41.5 41.5 3.19 48.0 48.0 3.42
1250 14.4 13.2 2.54 18.1 16.7 2.63 21.9 19.9 2.72 25.7 22.8 2.79 30.2 27.5 2.89 35.4 35.4 3.00 41.5 41.5 3.17 48.5 48.5 3.40
1375 14.6 13.4 2.58 18.4 16.9 2.66 22.1 20.1 2.74 26.0 23.1 2.81 30.5 27.8 2.89 35.7 35.7 3.00 41.8 41.8 3.16 48.9 48.9 3.39
75
1125 13.5 12.4 2.60 17.4 16.0 2.71 21.2 19.4 2.82 25.0 22.2 2.92 29.5 26.8 3.03 34.5 34.5 3.16 40.3 40.3 3.34 47.1 47.1 3.58
1250 13.8 12.7 2.63 17.7 16.2 2.74 21.5 19.6 2.84 25.3 22.5 2.92 29.8 27.1 3.02 34.8 34.8 3.15 40.8 40.8 3.31 47.7 47.7 3.55
1375 14.0 12.9 2.67 17.9 16.4 2.76 21.7 19.8 2.86 25.6 22.7 2.93 30.1 27.4 3.03 35.2 35.2 3.15 41.2 41.2 3.31 48.1 48.1 3.54
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
FX4ANF 042 1.00 1.00 CJ5A/CK5A/CK5BA 042 0.98 1.02
F(A,B)4AN(F,B,C) 042 0.98 1.02 048 0.98 1.01
FC4BN(F,B) 042 0.98 1.02 CJ5A/CK5A/CK5BN 042 0.98 1.02
FK4CNF 003 0.96 0.96 048 0.98 1.01
005 0.97 0.89 CJ5A/CK5A/CK5BW 048 0.98 1.01
FV4ANF 003 0.96 0.95 CK3BA 042 0.98 1.02
005 0.97 0.89 048 0.98 1.01
CE3AA 042 0.98 1.02
048 0.98 1.01
650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section
65
1225 17.3 15.9 2.61 21.5 19.8 2.74 25.7 23.4 2.86 30.0 26.6 2.99 35.1 32.0 3.14 41.1 41.1 3.34 40.4 40.4 3.30 39.5 39.5 3.21
1400 17.6 16.2 2.61 22.5 20.7 2.74 25.9 23.6 2.84 30.2 26.9 2.95 35.5 32.3 3.09 41.5 41.5 3.28 40.8 40.8 3.22 40.0 40.0 3.14
1575 17.8 16.4 2.62 21.9 20.2 2.73 26.1 23.8 2.83 30.5 27.1 2.93 35.8 32.6 3.06 41.9 41.9 3.24 41.2 41.2 3.18 40.4 40.4 3.09
70
1225 16.8 15.5 2.74 21.1 19.4 2.88 25.4 23.2 3.03 29.6 26.3 3.16 34.7 31.6 3.32 40.5 40.5 3.53 39.8 39.8 3.48 38.9 38.9 3.38
1400 17.1 15.7 2.75 21.4 19.6 2.87 25.6 23.4 3.00 29.9 26.6 3.12 35.0 31.9 3.27 41.0 41.0 3.46 40.2 40.2 3.40 39.4 39.4 3.30
1575 17.3 15.9 2.76 21.6 19.8 2.87 25.8 23.6 2.99 30.1 26.8 3.10 35.3 32.2 3.24 41.3 41.3 3.42 40.6 40.6 3.35 39.8 39.8 3.25
75
1225 16.3 15.0 2.88 20.6 19.0 3.02 25.1 22.9 3.19 29.3 26.0 3.34 34.3 31.2 3.51 40.0 40.0 3.73 39.2 39.2 3.66 38.3 38.3 3.56
1400 16.6 15.2 2.89 20.9 19.2 3.01 25.3 23.1 3.17 29.6 26.3 3.30 34.6 31.5 3.46 40.4 40.4 3.66 39.6 39.6 3.58 38.8 38.8 3.47
1575 16.8 15.4 2.90 21.2 19.4 3.01 25.5 23.3 3.16 29.8 26.5 3.28 34.9 31.8 3.42 40.8 40.8 3.61 40.0 40.0 3.53 39.1 39.1 3.41
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
FV4ANF 003 1.00 1.00 FX4ANF 042 1.02 1.01
F(A,B)4AN(F,B,C) 048 1.02 1.03 CE3AA 048 1.02 1.04
FC4BN(F,B) 048 1.02 1.02 CJ5A/CK5A/CK5BA 048 1.02 1.03
FK4CNF 003 0.99 1.00 CJ5A/CK5A/CK5BN 048 1.02 1.03
005 0.99 0.93 CJ5A/CK5A/CK5BW 048 1.02 1.03
FV4ANF 005 0.99 0.93 CK3BA 048 1.02 1.03