—14—
DETAILED COOLING CAPACITIES* Continued
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C).
** System kw is total of indoor and outdoor unit kilowatts.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
EWB—Entering Wet Bulb
EVAP
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh†
Total
Sys
Kw**
Capacity
MBtuh†
Total
Sys
Kw**
Capacity
MBtuh†
Total
Sys
Kw**
Capacity
MBtuh†
Total
Sys
Kw**
Capacity
MBtuh†
Total
Sys
Kw**
Capacity
MBtuh†
Total
Sys
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
650AN060-B,C Outdoor Section With FV4ANB006 Indoor Section
1750
72 70.1 35.6 4.43 66.6 34.4 4.92 63.1 33.1 5.47 59.2 31.7 6.07 55.0 30.3 6.73 50.2 28.7 7.42
67 64.4 45.5 4.35 61.3 44.2 4.85 58.0 42.9 5.40 54.5 41.5 6.00 50.6 40.0 6.65 46.4 38.4 7.35
63†† 60.2 44.3 4.30 57.2 43.0 4.79 54.2 41.7 5.34 50.9 40.3 5.94 47.3 38.8 6.60 43.4 37.1 7.30
62 59.2 55.1 4.29 56.4 53.7 4.78 53.5 52.3 5.33 50.5 50.4 5.93 47.5 47.5 6.60 44.2 44.2 7.32
57 57.8 57.8 4.27 55.6 55.6 4.77 53.1 53.1 5.32 50.5 50.5 5.93 47.5 47.5 6.60 44.2 44.2 7.32
2000
72 71.1 37.4 4.52 67.6 36.1 5.02 63.9 34.8 5.57 59.8 33.4 6.16 55.5 32.0 6.81 50.6 30.4 7.51
67 65.5 48.5 4.44 62.2 47.2 4.94 58.8 45.9 5.49 55.1 44.4 6.09 51.1 42.9 6.74 46.8 41.2 7.44
63†† 61.2 47.1 4.39 58.1 45.8 4.88 54.9 44.4 5.43 51.6 43.0 6.03 47.9 41.5 6.68 43.8 39.7 7.39
62 60.5 59.0 4.38 57.7 57.4 4.88 54.9 54.9 5.43 52.1 52.1 6.04 48.9 48.9 6.70 45.3 45.3 7.42
57 60.1 60.1 4.38 57.6 57.6 4.88 54.9 54.9 5.43 52.1 52.1 6.04 49.0 49.0 6.70 45.4 45.4 7.42
2250
72 72.0 39.1 4.61 68.3 37.8 5.10 64.4 36.5 5.65 60.4 35.1 6.25 55.9 33.7 6.90 50.8 32.0 7.59
67 66.2 51.4 4.53 62.9 50.1 5.03 59.4 48.7 5.57 55.6 47.3 6.17 51.7 45.7 6.83 47.1 43.9 7.53
63†† 61.9 49.8 4.48 58.8 48.5 4.97 55.6 47.1 5.52 52.1 45.6 6.12 48.3 44.0 6.77 44.1 42.1 7.48
62 61.8 61.8 4.48 59.2 59.2 4.98 56.5 56.5 5.53 53.5 53.5 6.14 50.2 50.2 6.80 46.4 46.4 7.51
57 61.8 61.8 4.48 59.2 59.2 4.98 56.4 56.4 5.53 53.4 53.4 6.14 50.2 50.2 6.80 46.4 46.4 7.51
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
FV4ANB 006 1.00 1.00 FX4ANB 060 0.98 1.04
FB4ANB 070 0.98 1.04 CC5A/CD5AW 060 0.97 0.99
FC4BNB 070 0.98 1.04 CJ5A/CK5A/CK5BX 060 0.97 1.00
FK4CNB 006 1.00 1.00 — — —