DETAILED COOLING CAPACITIES* Continued
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor
unit is located above outdoor unit, a slight variation in capacity may occur.
Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
Sensible capacities shown are based on 80°F entering air at the indoor coil. For sensible capacities at other than 80°F, deduct 835 Btuh per 1000 CFM of
indoor coil air for each degree below 80°F, or add 835 Btuh per 1000 CFM of indoor coil air per degree above 80°F. When the required data falls between
the published data, interpolation may be performed.
** Unit kW is total of indoor and outdoor unit kilowatts.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
85 95 105 115 125
CFM EWB
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**Total Sens Total Sens Total Sens Total Sens Total Sens
593C060-C Outdoor Section With CC5A/CD5AW060 Indoor Section
1750
72 66.9 33.0 5.85 63.9 31.9 6.39 60.7 30.7 6.97 57.3 29.5 7.61 53.8 28.2 8.29
67 61.1 41.8 5.70 58.3 40.6 6.23 55.4 39.4 6.80 52.3 38.1 7.43 48.9 36.8 8.09
62 55.7 50.3 5.56 53.1 49.0 6.08 50.4 47.6 6.65 47.5 46.0 7.25 44.0 43.8 7.86
57 53.2 53.2 5.50 51.3 51.3 6.03 49.1 49.1 6.61 46.7 46.7 7.22 43.8 43.8 7.86
2000
72 68.1 34.5 5.98 64.9 33.3 6.52 61.6 32.1 7.11 58.1 30.9 7.74 54.4 29.6 8.43
67 62.3 44.2 5.82 59.3 43.0 6.35 56.2 41.8 6.93 53.0 40.5 7.56 49.5 39.2 8.22
62 56.8 53.4 5.69 54.1 52.0 6.21 51.3 50.4 6.78 48.5 48.4 7.39 45.5 45.5 8.04
57 55.2 55.2 5.65 53.1 53.1 6.18 50.8 50.8 6.76 48.4 48.4 7.39 45.4 45.4 8.04
2250
72 69.0 35.8 6.10 65.7 34.7 6.64 62.3 33.4 7.23 58.7 32.2 7.87 55.0 30.9 8.55
67 63.1 46.6 5.95 60.1 45.4 6.48 56.9 44.1 7.05 53.6 42.8 7.68 50.0 41.5 8.35
62 57.7 56.2 5.81 55.0 54.5 6.33 52.3 52.3 6.90 49.7 49.7 7.54 46.8 46.8 8.21
57 56.9 56.9 5.79 54.7 54.7 6.32 52.3 52.3 6.91 49.7 49.7 7.54 46.8 46.8 8.21
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Unit
Size
Cooling
Indoor
Section
Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 060 0.96 0.98 CK5A/CK5BT
060
0.97 0.95
CC5A/CD5AW 060 1.00 1.00 CK5A/CK5BX
060
0.98 0.93
CE3AA 060 1.01 1.00
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CK3BA 060 0.96 0.98 CC5A/CD5AA
060
0.96 0.95
CK5A/CK5BA 060 0.96 0.98 CC5A/CD5AW
060
0.97 0.94
CK5A/CK5BN 060 0.96 0.99 CE3AA
060
0.98 0.95
CK5A/CK5BX 060 1.00 1.00 CK3BA
060
0.97 0.95
F(A,B)4(A,B)N(F,B) 060 1.01 1.04 CK5A/CK5BA
060
0.97 0.95
FB4(A,B)NB 070 1.03 1.02 CK5A/CK5BT
060
0.97 0.95
FC4(B,C)N(F,B) 060 1.01 1.04 CK5A/CK5BX
060
0.98 0.93
FC4(B,C)NB 070 1.03 1.02
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
FG3AAA 060 0.99 0.99 CC5A/CD5AA
060
0.96 0.94
FK4(C,D)NB 006 1.02 0.98 CC5A/CD5AW
060
0.97 0.94
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CE3AA
060
0.98 0.94
CC5A/CD5AA
060
0.96 0.95 CK3BA
060
0.97 0.95
CE3AA
060
0.98 0.94 CK5A/CK5BA
060
0.97 0.95
CK3BA
060
0.97 0.95 CK5A/CK5BT
060
0.97 0.95
CK5A/CK5BA
060
0.97 0.95 CK5A/CK5BX
060
0.98 0.93