DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
85 95 105 115 125
CFM EWB
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**
Capacity
MBtuh
Total
System
kW**Total Sens Total Sens Total Sens Total Sens Total Sens
593C036-C, D Outdoor Section With CC5A/CD5AA036 Indoor Section
1050
72 39.6 19.6 3.42 37.4 18.8 3.65 35.2 18.0 3.88 32.9 17.2 4.08 30.5 16.4 4.28
67 36.0 24.9 3.32 34.0 24.0 3.54 31.9 23.2 3.75 29.8 22.3 3.94 27.7 21.5 4.12
62 32.7 29.8 3.23 30.7 28.9 3.43 28.8 27.8 3.62 27.0 26.7 3.79 25.3 25.3 3.98
57 31.3 31.3 3.19 29.8 29.8 3.39 28.3 28.3 3.59 26.8 26.8 3.79 25.3 25.3 3.98
1200
72 40.3 20.5 3.49 38.1 19.7 3.73 35.8 18.9 3.96 33.3 18.1 4.17 31.0 17.3 4.38
67 36.7 26.4 3.40 34.6 25.5 3.62 32.4 24.7 3.83 30.3 23.9 4.03 28.1 23.0 4.21
62 33.4 31.8 3.31 31.4 30.7 3.51 29.5 29.4 3.71 27.8 27.8 3.90 26.2 26.2 4.10
57 32.6 32.6 3.29 31.1 31.1 3.50 29.5 29.5 3.71 27.8 27.8 3.90 26.2 26.2 4.10
1350
72 40.8 21.4 3.56 38.5 20.6 3.80 36.1 19.7 4.03 33.6 18.9 4.25 31.4 18.1 4.47
67 37.2 27.9 3.47 35.0 27.0 3.69 32.8 26.1 3.91 30.6 25.3 4.11 28.3 24.3 4.29
62 34.0 33.5 3.38 32.1 32.1 3.59 30.4 30.4 3.80 28.6 28.6 4.00 26.9 26.9 4.20
57 33.7 33.7 3.38 32.1 32.1 3.59 30.4 30.4 3.80 28.6 28.6 4.00 26.9 26.9 4.21
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Unit
Size
Cooling
Indoor
Section
Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 036 1.00 1.00 CK5A/CK5BE 042 0.99 0.91
042 1.00 1.00 CK5A/CK5BT 036 0.99 0.92
CC5A/CD5AW 042 1.00 1.00 042 0.99 0.92
CD5AW 036 1.00 1.00 CK5A/CK5BW 036 0.99 0.92
CE3AA 036 0.99 1.00
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
042 1.00 1.00 CC5A/CD5AA 036 0.99 0.92
CF5AA 036 1.00 1.00 042 0.99 0.91
CK3BA 036 1.00 1.00 CC5A/CD5AW 036 0.99 0.92
042 1.00 1.00 042 0.99 0.91
CK5A/CK5BA 036 1.00 1.00 CE3AA 036 0.98 0.91
042 1.00 1.00 042 0.99 0.91
CK5A/CK5BN 036 0.92 0.97 CK3BA 036 0.99 0.92
042 0.97 1.00 042 0.99 0.91
CK5A/CK5BW 036 1.00 1.00 CK5A/CK5BA 036 0.99 0.92
F(A,B)4(A,B)NF 036 0.98 1.01 042 0.99 0.91
F(A,B)4(A,B)N(F,B) 042 1.01 1.01 CK5A/CK5BT 036 0.99 0.92
FC4(B,C)NF 036 0.98 1.01 042 0.99 0.91
FC4(B,C)N(F,B) 042 1.01 1.01 CK5A/CK5BW 036 0.99 0.92
FG3AAA 036 0.98 0.99
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
FK4(C,D)NB 005 1.02 0.95 CC5A/CD5AA 042 0.99 0.91
006 1.02 0.95 CC5A/CD5AW 036 0.99 0.92
FK4(C,D)NF 001 1.00 0.98 042 0.99 0.91
002 1.00 0.98 CE3AA 036 0.98 0.92
003 1.01 0.94 042 0.99 0.91
005 1.02 0.93 CK3BA 042 0.99 0.91
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CK5A/CK5BA 042 0.99 0.91
CC5A/CD5AA 036 0.99 0.94 CK5A/CK5BW 036 0.99 0.92
CE3AA 036 0.98 0.93
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
042 0.99 0.93 CC5A/CD5AA 042 0.99 0.90
CK3BA 036 0.99 0.94 CC5A/CD5AW 036 0.99 0.92
CK5A/CK5BA 036 0.99 0.94 042 0.99 0.91
CK5A/CK5BE 042 0.99 0.93 CE3AA 036 0.98 0.91
CK5A/CK5BT 036 0.99 0.94 042 0.99 0.91
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CK3BA 042 0.99 0.91
CC5A/CD5AA 036 0.99 0.92 CK5A/CK5BA 042 0.99 0.91
042 0.99 0.91 CK5A/CK5BT 042 0.99 0.91
CC5A/CD5AW 036 0.99 0.92 CK5A/CK5BW 036 0.99 0.92
CE3AA 036 0.98 0.92
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
042 0.99 0.92 CC5A/CD5AA 036 1.00 0.92
CK3BA 036 0.99 0.92 CK3BA 036 0.98 0.94
042 0.99 0.92 042 0.98 0.93
CK5A/CK5BA 036 0.99 0.92 CK5A/CK5BA 042 0.98 0.93
042 0.99 0.92 CK5A/CK5BW 036 0.98 0.94