ELECTRICAL DATA
UNIT SIZE ---
SERIES
V/PH
OPER VOLTS* COMPR FAN
MCA
MIN
WIRE
SIZE†
MIN
WIRE
SIZE†
MAX
LENGTH
ft(m)‡
MAX
LENGTH
ft(m)‡
MAX
FUSE**
or CKT
BRK
AMPS
MAX MIN LRA RLA FLA 60° C 75° C 60° C 75° C
018---E
208/230/1 253 197
48.0 9.0 0.8 12.0 14 14 66 (20.1) 62 (18.9) 20
024---C 58.3 12.8 0.75 16.8 14 14 47 (14.3) 45 (13.7) 25
030---D 77.0 16.0 0.8 20.8 12 12 58 (17.7) 56 (17.1) 30
036---D 79.0 16.7 0.9 21.7 12 12 58 (17.7) 55 (16.8) 35
042---C 109.0 19.9 1.2 26.0 10 10 77 (23.5) 73 (22.3) 40
048---D 117.0 21.8 1.2 28.4 8 8 109 (33.2) 104(31.7) 50
060---D 134.0 26.3 1.2 34.1 8 8 91( 27.7) 87 (26.5) 50
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30_C, consult table 310---16 of the NEC (ANSI/NFPA70). The ampacity of non--- metallic---sheathed cable (NM),
trade name ROMEX, sh al l be th at of 60_C conditions, per the NEC (ANSI/NFPA 70)Article 336---26. If other than uncoated (no---plated), 60 or75_C
insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA
70).
} Length shown is as measured1 way alongwirepath between unit and service panel for voltagedropnot to exceed2%.
** Time---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- RatedLoadAmps
NOTE: Control circuit is 24---V on allunitsand requiresexternalpower source. Copper wire mustbe used from service disconnect to unit.
Allmotors/compressorscontain internal overload protection.
Complies with 2001requirements ofASHRAE Standards 90.1
A--WEIGHTED SOUND POWER
UNIT SIZE --- SERIES
STANDARD
RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA , without tone adjustment)
125 250 500 1000 2000 4000 8000
018---E 74 52.0 63.5 68.0 70.5 66.5 62.0 57.5
024---C 75 54.5 64.0 69.0 69.5 67.5 64.0 58.0
030---D 74 52.0 62.5 66.5 68.5 65.0 63.5 59.0
036---D 72 55.0 62.0 63.5 66.0 64.0 61.5 54.0
042---C 77 55.5 60.0 63.5 71.5 65.0 62.5 59.0
048---D 77 58.0 65.5 68.5 72.0 66.5 60.5 53.0
060---D 77 55.0 63.0 67.5 71.5 68.0 64.0 60.5
NOTE: Tested in accordance with ARI Standard 270---95 (not listed in ARI).
A--WEIGHTED SOUND POWER WITH SOUND HOOD
UNIT SIZE --- SERIES
STANDARD
RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA , without tone adjustment)
125 250 500 1000 2000 4000 8000
018---E 73 52.5 63.0 67.5 69.0 66.0 62.0 55.5
024---C 74 54.0 63.5 69.0 69.0 67.5 63.5 57.5
030---D 74 51.5 62.0 66.5 67.5 64.5 62.0 57.5
036---D 70 54.5 62.0 63.5 64.5 63.0 60.0 51.5
042---C 75 55.0 60.5 63.5 69.0 64.5 61.5 56.0
048---D 74 58.0 64.5 69.0 68.5 66.0 60.0 53.0
060---D 74 55.0 63.5 67.0 69.0 66.5 62.0 57.0
NOTE: Tested in accordance with ARI Standard 270---95 (not listed in ARI).
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE---SERIES REQUIRED SUBCOOLING °F (°C)
018---E 10 (5.6)
024---C 12 (6.7)
030---D 12 (6.7)
036---D 9 (5.0)
042---C 11 (6.1)
048---D 11 (6.1)
060---D 12 (6.7)