DETAILED COOLING CAPACITIES
#
EVAPORATORAIR
CONDENSER ENTERING AIRTEMPERATURES °F (°C)
75(23.9) 85(29.4) 95(35) 105(40.6) 115 (46.1) 125 (51.7)
CFM
EWB
°F(°C)
CapacityMBtuh
Total
System
KW**
CapacityMBtuh
Total
System
KW**
CapacityMBtuh
Total
System
KW**
CapacityMBtuh
Total
System
KW**
CapacityMBtuh
Total
System
KW**
CapacityMBtuh
Total
System
KW**
Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
213ANA060---DOutdoor Se ction WithFY4ANB060Indoor Section
1750
72(22.2) 70.34 35.38 4.52 67.10 34.14 4.98 63.63 32.83 5.48 60.01 31.48 6.03 56.06 30.03 6.63 51.70 28.45 7.27
67(19.4) 64.72 44.25 4.46 61.72 42.98 4.92 58.50 41.62 5.42 55.15 40.23 5.97 51.50 38.73 6.57 47.50 37.11 7.21
63(17.2)†† 60.52 42.98 4.41 57.68 41.67 4.87 54.66 40.31 5.37 51.50 38.90 5.92 48.09 37.40 6.52 44.37 35.78 7.17
62(16.7) 59.39 53.03 4.40 56.60 51.67 4.86 53.67 50.23 5.36 50.63 48.68 5.91 47.46 47.46 6.51 44.40 44.40 7.17
57(13.9) 57.36 57.36 4.38 55.12 55.12 4.84 52.73 52.73 5.35 50.21 50.21 5.90 47.45 47.45 6.51 44.40 44.40 7.17
2000
72(22.2) 71.28 36.87 4.64 67.97 35.64 5.09 64.37 34.31 5.59 60.64 32.95 6.14 56.56 31.48 6.74 52.07 29.88 7.39
67(19.4) 65.71 46.88 4.58 62.60 45.59 5.03 59.26 44.22 5.53 55.79 42.80 6.08 52.01 41.28 6.69 47.89 39.62 7.33
63(17.2)†† 61.54 45.45 4.53 58.58 44.14 4.99 55.44 42.75 5.49 52.17 41.32 6.04 48.63 39.78 6.64 44.80 38.11 7.28
62(16.7) 60.48 56.64 4.52 57.63 55.18 4.98 54.66 54.31 5.48 51.85 51.85 6.03 48.91 48.91 6.64 45.66 45.66 7.30
57(13.9) 59.46 59.46 4.51 57.07 57.07 4.97 54.53 54.53 5.48 51.85 51.85 6.03 48.92 48.92 6.64 45.67 45.67 7.30
2250
72(22.2) 71.96 38.30 4.75 68.56 37.06 5.21 64.87 35.72 5.71 61.04 34.35 6.26 56.86 32.87 6.86 52.26 31.26 7.50
67(19.4) 66.40 49.38 4.70 63.21 48.09 5.15 59.77 46.69 5.65 56.21 45.25 6.20 52.34 43.69 6.80 48.13 41.98 7.44
63(17.2)†† 62.26 47.81 4.65 59.21 46.48 5.10 55.98 45.06 5.60 52.62 43.60 6.15 49.00 42.02 6.75 45.07 40.30 7.40
62(16.7) 61.41 59.80 4.64 58.65 58.65 5.10 55.97 55.97 5.61 53.15 53.15 6.16 50.06 50.06 6.77 46.64 46.64 7.42
57(13.9) 61.16 61.16 4.64 58.65 58.65 5.10 55.97 55.97 5.61 53.16 53.16 6.16 50.07 50.07 6.77 46.65 46.65 7.42
COOLINGINDOOR
MODEL
CAPACITY POWER FURNACEMODEL
*FY4ANB060 1.00 1.00
FE4ANB006 1.02 0.98
FV4BNB006 1.02 0.96
FX4CN(B,F)060 1.01 0.97
CAP**6021A** 0.99 0.99
CAP**6024A** 0.99 0.99
CNPH*6024A** 0.99 0.99
CNPV*6024A** 0.99 0.99
CSPH*6012A** 1.00 1.00
CAP**6021A** 0.99 0.97 315(A,J)AV060110
CNPH*6024A** 0.99 0.97 315(A,J)AV060110
CSPH*6012A** 1.00 0.98 315(A,J)AV060110
CAP**6024A** 0.99 0.97 315(A,J)AV066135
CNPH*6024A** 0.99 0.97 315(A,J)AV066135
CNPV*6024A** 0.99 0.97 315(A,J)AV066135
COOLINGINDOOR
MODEL
CAPACITY POWER FURNACEMODEL
CSPH*6012A** 1.00 0.96 315(A,J)AV066135
CAP**6024A** 1.00 0.96 315(A,J)AV066155
CNPH*6024A** 0.99 0.96 315(A,J)AV066155
CNPV*6024A** 0.99 0.96 315(A,J)AV066155
CSPH*6012A** 1.00 0.96 315(A,J)AV066155
CNPH*6024A** 0.98 1.01 353AAV048080
CSPH*6012A** 0.98 1.01 353AAV048080
CAP**6021A** 0.99 0.97 353AAV060100
CNPH*6024A** 0.99 0.97 353AAV060100
CSPH*6012A** 0.99 0.97 353AAV060100
CAP**6024A** 0.99 0.97 353AAV060120
CNPH*6024A** 0.99 0.97 353AAV060120
CNPV*6024A** 0.99 0.97 353AAV060120
CSPH*6012A** 1.00 0.98 353AAV060120
CAP**6021A** 0.98 0.98 355(A,C)AV060100
COOLINGINDOOR
MODEL
CAPACITY POWER FURNACEMODEL
CSPH*6012A** 0.99 0.99 355(A,C)AV060100
CAP**6024A** 0.98 0.98 355(A,C)AV060120
CNPH*6024A** 0.98 0.98 355(A,C)AV060120
CNPV*6024A** 0.98 0.98 355(A,C)AV060120
CSPH*6012A** 0.99 0.99 355(A,C)AV060120
CAP**6021A** 0.99 0.97 313*AV048090
CNPH*6024A** 0.98 0.97 313*AV048090
CSPH*6012A** 0.99 0.97 313*AV048090
CAP**6021A** 1.00 0.98 313*AV060110
CNPH*6024A** 0.99 0.97 313*AV060110
CSPH*6012A** 1.00 0.98 313*AV060110
CAP**6024A** 0.99 0.97 313*AV060135
CNPH*6024A** 0.99 0.97 313*AV060135
CNPV*6024A** 0.99 0.97 313*AV060135
CSPH*6012A** 1.00 0.98 313*AV060135
* Tested combination.
{ Total and sensible capacities are net capacities. B lower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F(27_C) entering air at the indoorcoil. For sensible capacitiesat other than 80_F(27_ C), deduct835Btuh
(245 kW) per 1000CFM (480 L/S) of in door coil air for each degree below 80_F(27_C ) , or add835 Btuh (245kW) per 1000CFM (480 L/S) ofindoor coil air per degree above 80_F(27_C).
# Detailed cool ing capacities are basedon indoor and outdoor unit atthe same elevation per ARIstandard 210/240---94. If additional tubingl ength and/or indoor unitis locatedabove outdoorunit,a slight variation in capacitymay
occur.
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVArating indoor condition (75_F edb/63_F ewb).All other in door air temperaturesare at80_F edb.
NOTE: When the required data falls between the published data, i nterpolation may be performed. Extrapolation is not an acceptable practice.
EWB —Entering Wet Bulb
213A