Bryant 124A Air Conditioner User Manual


 
29
DETAI LED COOLING CAPACI TI ES# (CONTINUED)
EVAPORATORAIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75 (23.9) 85(29.4) 95 (35) 105 (40.6) 115(46.1) 125 (51.7)
CFM
EWB
°F(°C)
Capacity MBtuh
Total
Sys.
KW**
Capacity MBtuh
Total
Sys.
KW**
Capacity MBtuh
Total
Sys.
KW**
Capacity MBtuh
Total
Sys.
KW**
Capacity MBtuh
Total
Sys.
KW**
Capacity MBtuh
Total
Sys.
KW**
Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
124ANA060---C Outdoor Section With CAP**6024A** Indoor Section
1750
72 (22.2) 70.52 37.08 3.97 67.20 35.81 4.38 63.70 34.48 4.83 59.99 33.10 5.32 55.97 31.62 5.86 51.51 30.01 6.45
67 (19.4) 64.33 45.47 3.92 61.31 44.20 4.33 58.13 42.87 4.78 54.75 41.49 5.27 51.12 40.02 5.82 47.11 38.42 6.40
62 (16.7) 58.81 53.84 3.87 56.12 52.55 4.28 53.31 51.19 4.73 50.40 49.71 5.23 47.55 47.55 5.78 44.50 44.50 6.38
57 (13.9) 57.17 57.17 3.86 55.01 55.01 4.27 52.72 52.72 4.73 50.25 50.25 5.23 47.55 47.55 5.78 44.50 44.50 6.38
2000
72 (22.2) 71.76 38.86 4.07 68.29 37.57 4.48 64.63 36.22 4.93 60.76 34.81 5.43 56.59 33.31 5.96 51.97 31.67 6.55
67 (19.4) 65.49 48.34 4.02 62.33 47.04 4.43 59.00 45.69 4.88 55.50 44.28 5.37 51.73 42.78 5.92 47.58 41.13 6.50
62 (16.7) 60.13 57.72 3.98 57.39 56.32 4.38 54.66 54.66 4.84 52.02 52.02 5.34 49.12 49.12 5.89 45.84 45.84 6.48
57 (13.9) 59.48 59.48 3.97 57.15 57.15 4.38 54.68 54.68 4.84 52.03 52.03 5.34 49.12 49.12 5.89 45.85 45.85 6.48
2250
72 (22.2) 72.67 40.54 4.17 69.08 39.23 4.58 65.29 37.86 5.03 61.30 36.43 5.52 57.00 34.90 6.06 52.25 33.24 6.64
67 (19.4) 66.34 51.06 4.12 63.07 49.75 4.53 59.64 48.38 4.98 56.04 46.94 5.47 52.17 45.40 6.01 47.92 43.68 6.60
62 (16.7) 61.32 61.32 4.08 58.90 58.90 4.49 56.27 56.27 4.95 53.45 53.45 5.45 50.38 50.38 6.00 46.91 46.91 6.59
57 (13.9) 61.37 61.37 4.08 58.90 58.90 4.49 56.27 56.27 4.95 53.46 53.46 5.45 50.38 50.38 6.00 46.92 46.92 6.59
COOLING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
*CAP**6024A** 1.00 1.00
CAP**6021A** 0.98 1.03
CNPH*6024A** 0.98 0.98
CNPV*6024A** 0.98 0.98
CSPH*6012A** 0.98 0.98
FE4ANB006 1.00 0.96
FV4BNB006 1.00 0.96
FX4CN(B,F)060 1.01 1.01
FY4ANB060 1.00 1.04
CNPH*6024A** 0.97 0.97 315(A,J)AV060110
CNPV*6024A** 0.97 0.97 315(A,J)AV060110
CSPH*6012A** 0.97 0.97 315(A,J)AV060110
CAP**6024A** 0.98 0.98 315(A,J)AV066135
CNPH*6024A** 0.97 0.97 315(A,J)AV066135
CNPV*6024A** 0.97 0.97 315(A,J)AV066135
CSPH*6012A** 0.97 0.97 315(A,J)AV066135
COOLING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CAP**6024A** 0.98 0.98 315(A,J)AV066155
CNPH*6024A** 0.98 0.98 315(A,J)AV066155
CNPV*6024A** 0.98 0.98 315(A,J)AV066155
CSPH*6012A** 0.98 0.98 315(A,J)AV066155
CNPH*6024A** 0.97 0.97 353AAV048080
CSPH*6012A** 0.97 0.97 353AAV048080
CAP**6021A** 0.97 0.97 353AAV060100
CNPH*6024A** 0.97 0.97 353AAV060100
CSPH*6012A** 0.97 0.97 353AAV060100
CAP**6024A** 0.97 0.96 353AAV060120
CNPH*6024A** 0.97 0.96 353AAV060120
CNPV*6024A** 0.97 0.96 353AAV060120
CSPH*6012A** 0.97 0.96 353AAV060120
CAP**6021A** 0.94 0.94 355(A,C)AV060080
CNPH*6024A** 0.94 0.94 355(A,C)AV060080
CSPH*6012A** 0.95 0.95 355(A,C)AV060080
COOLING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6024A** 0.94 0.94 355(A,C)AV060100
CSPH*6012A** 0.95 0.95 355(A,C)AV060100
CNPH*6024A** 0.94 0.94 355(A,C)AV060120
CNPV*6024A** 0.94 0.94 355(A,C)AV060120
CSPH*6012A** 0.95 0.95 355(A,C)AV060120
CAP**6021A** 0.97 0.96 313*AV048090
CNPH*6024A** 0.97 0.97 313*AV048090
CSPH*6012A** 0.97 0.96 313*AV048090
CAP**6021A** 0.97 0.96 313*AV060110
CNPH*6024A** 0.97 0.96 313*AV060110
CSPH*6012A** 0.98 0.97 313*AV060110
CAP**6024A** 0.97 0.96 313*AV060135
CNPH*6024A** 0.97 0.96 313*AV060135
CNPV*6024A** 0.97 0.96 313*AV060135
CSPH*6012A** 0.97 0.96 313*AV060135
See notes on page 29
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F(27_C) entering air at the indoor coil. For sensible capacities at other than 80_F(27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for ea ch degree below 80_F(27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F(27_C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may
occur.
** System kw is total of indoor and outdoor unit kilowatts.
EWB — Entering Wet Bulb
NOTE: When the required data fall between the publis hed data, interpolation may be pe rformed. Extrapolation is not an acceptable practice.
124A